Logic
De nition
Step-by-step
STEP-BY-STEP
movement
MOVEMNT
Encoder
Encoder
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses du-
IBL OPEN
ring opening
Block pulses
IBL TCA
during TCA
Block pulses
IBL CLOSE
during closing
Open in other
OPEN IN OTHER
direction
DIRECT.
Con guration
of safety input
SAFE 1
SAFE 1.
72
Con guration
of safety input
SAFE 2
SAFE 2.
74
Con guration
of safety input
SAFE 3
SAFE 3.
77
38 -
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120
INSTALLATION MANUAL
Cross out
Default
setting
used
Inputs con gured as Start E, Start I,
0
Ped operate with 4-step logic.
Inputs con gured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
0
Inputs con gured as Start E, Start
2
I, Ped operate with 2-step logic.
Movement reverses with each pulse.
Operation with encoder disabled
This setting fully disables the anti-crush safety
device, with serious safety risks.
0
Install active safety edges on closing and opening or
switch to deadman operation. (see Deadman logic)
The slowing down spaces are an estimate made
through the gate travel time.
For greater precision on the slowing down point,
set encoder = 1 or 2.
Operation with encoder used as position sensor for
2
acquiring slow-down distances. - Gate detection
1
locked out. Manual setting of "opening force", "clo-
sing force", "opening slow-down force" and "closing
slow-down force" parameters.
2
LEO B CBB DL2 3
Automatic mode with encoder: slow-down and
120 F02
obstacle detection performed by means of enco-
(only for sw ver-
der. Adjustment of obstacle detection sensitivity
sions 7.08)
(opening force, closing force, opening slow-down
LEO B CBB DL2 3 120
force, closing slow-down force parameters) (de-
F02 PHOT USA16
fault setting).
(only for sw ver-
sions 8.08)
0
The ashing light comes on at the same time as the motor(s) start.
0
1
The ashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is con gured as OPEN UP.
Input 62 is con gured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
0
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman mode is
enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
Input 61 is con gured as OPEN UP.
2
Input 62 is con gured as CLOSE UP.
0
Pulse from inputs con gured as Start E, Start I, Ped has e ect during opening.
0
1
Pulse from inputs con gured as Start E, Start I, Ped has no e ect during opening.
0
Pulse from inputs con gured as Start E, Start I, Ped has e ect during TCA pause.
0
1
Pulse from inputs con gured as Start E, Start I, Ped has no e ect during TCA pause.
0
Pulse from inputs con gured as Start E, Start I, Ped has e ect during closing.
0
1
Pulse from inputs con gured as Start E, Start I, Ped has no e ect during closing.
0
Standard operating mode (Fig.G Rif. 1).
0
1
Opens in other direction to standard operating mode (Fig. G Rif.2)
0
Input con gured as Phot (photocell).
0
1
Input con gured as Phot test (tested photocell).
2
Input con gured as Phot op (photocell active during opening only).
3
Input con gured as Phot op test (tested photocell active during opening only).
4
Input con gured as Phot cl (photocell active during closing only).
6
5
Input con gured as Phot cl test (tested photocell active during closing only).
6
Input con gured as Bar, safety edge.
7
Input con gured as Bar, tested safety edge.
8
Input con gured as Bar 8k2 (Inactive on SAFE 3).
9*
Input con gured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
Input con gured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing,
10*
the movement stops.
2
Input con gured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
11*
movement stops.
(Inactive on SAFE 3).
12*
Input con gured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
Input con gured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
13*
the movement stops.
Input con gured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
14*
movement stops.
(Inactive on SAFE 3).
F02-LEO B CBB DL2 3 120 F02 PHOT USA16
Optional extras
CLOSED
DURING
CLOSING
OPEN
DURING
OPENING
AFTER STOP
WARNING
WARNING: Check that the force of impact measured at
the points provided for by standard EN 12445 is lower
than the value laid down by standard EN 12453.
result in damage to property and injury to people
and animals.
WARNING: safety devices are not enabled.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
step-by-step mov.
2 STEP
3 STEP
4 STEP
OPENS
OPENS
OPENS
STOPS
CLOSES
CLOSES
CLOSES
STOP + TCA STOP + TCA
OPENS
OPENS
OPENS
WARNING: Setting sensitivity incorrectly can