Possible Failures And Their Elimination - OFFCAR 900 Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.6.1. POSSIBLE FAILURES AND THEIR ELIMINATION

Warning! : Only technically qualified service centres can perform the operations
described below!
Warning! :
Before resetting the safety thermostat, it is always necessary to
eliminate the problem causing its activation!
Problem and possible cause
T
HE MAIN BURNER DOES NOT LIGHT UP
- The ignition plug is not fixed
correctly or it is badly connected.
-
The
piezoelectric
damaged.
- There is a loss of pressure in gas
supply.
-
The injector is clogged or the
gas cock is damaged.
-
The pilot burner turns off when
the control knob or the ignition
button is released
- The thermocouple is not heated
sufficiently by the pilot burner.
- The gas cock is faulty
The pilot burner is on but the
main burner does not light
- Loss of pressure in the gas supply
- The injector is clogged or the gas
cock is damaged
- The gas outlet holes are clogged
The heating vat temperature
cannot be adjusted
- The bulb is faulty.
- The thermostat is faulty.
Instruction manual for installation, maintenance and use
GAS TILTING BRATT PANS Serie 900
Access to components and operation
Even a normal use of the appliance may cause
operation inconveniences and failures. The most
common problems are the following.
Ignition plug and thermocouple
igniter
is
Remove the lower front panel.
Remove the igniter cable and loosen the screws
of pilot burner support
Replace the plug and install the new plug working in
the opposite order.
Remove the thermocouple by loosening the
screws of pilot burner support
Replace the thermocouple and install the new
thermocouple working in the opposite order.
Unscrew
connections, remove the bulb from its seat.
Loosen both screws that fix the gas valve with a
suitable spanner.
Install a new valve in the opposite order.
gas
pipe
and
- GB -
thermocouple
16 di 36