Light Sensor; Explanation Of Functions - Becker Centronic Timecontrol TC52 Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour Centronic Timecontrol TC52:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Put the protective caps back on the power supply unit.
3. Fit the power supply unit in the socket.
4. Place the control panel in the frame and insert this into the power supply
unit.
A light sensor can be connected to the unit; see Assembly
and Operating Instructions for the Centronic SensorControl
SC43.
Roller shutter selection
With the roller shutter function, the roller shutter runs in maintained operation
mode after a travel button is pressed.
Venetian blind selection
With the venetian blind function, the venetian blind runs in touch mode to facil-
itate precise positioning of the laths. If you press a travel button for longer than
1 second, the venetian blind runs in maintained operation mode.
After moving to the programmed intermediate and end positions, the laths
automatically tilt (if the tilt position was programmed).
Manual/Automatic slide switch
In slide switch position
(e.g.: UP, STOP, DOWN via button actuation).
In slide switch position
shade function, twilight function, time, Astro function,...)
Alarm pilot light
An alarm signal is signalled by an illuminated alarm pilot light. A continuous
switching signal at the group or individual control inputs for longer than 5
seconds is deemed an alarm signal.
Group control unit
Several drives controlled simultaneously are referred to as a group.

Light sensor

Explanation of functions

only manual drive commands can be performed
automatic drive commands are performed (e.g.
45 - en

Publicité

Table des Matières
loading

Table des Matières