Connection as drive controller
Caution
Risk of injury due to electric shock.
Connection may only be performed by a qualified techni-
cian!
Attention
If this unit is used to control more than one drive, the
drives must be decoupled by relay controls. There is no
need for decoupling in the case of Becker drives with
electronic limit switching.
Always take into account the device switching current.
1. Connect the power supply unit as follows:
Jumper
2. Put the protective caps back on the power supply unit.
3. Fit the power supply unit in the socket.
4. Place the control panel in the frame and insert this into the power supply
unit.
green-yellow
blue
brown/black
black/brown
INDIVIDUAL
CENTRAL
Tubular drive
Connection for
light sensor
43 - en