5.4 electrical connection of the cable plug
Warning!
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
If the protective conductor is not connected, there is a risk of electric
shock!
▶ Always connect protective conductor and check electrical continuity
between coil and body.
Procedure:
Tighten cable plug (e.g. Type 2508 or other suitable cable plug),
observing max. torque 1 Nm.
Check that seal is fitted correctly.
Connect protective conductor and check electrical continuity between
coil and body.
8
6

MainTenance, TrOuBleshOOTing

6.1 safety instructions
Danger!
Risk of injury from high pressure in the equipment!
▶ Before loosening the lines and valves, turn off the pressure and vent
the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
Warning!
Risk of injury from improper maintenance!
▶ Maintenance may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
7
spare parTs
Caution!
Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries and
damage the device and the surrounding area.
▶ Use only original accessories and original spare parts from Bürkert.

7.1 Ordering spare parts

The following spare parts are available for the solenoid valve Type
0404 and 5404:
• Coil set (Pos. 1)
• Wearing parts set pilot control (Pos. 2)
• Wearing parts set fitting (Pos. 3)
Order the spare parts sets quoting the positions and the identification
number of the device.
10
english
english
Authorized cable plug
e.g. Type 2508 or other suitable
cable plug in accordance with
DIN EN 175301-803 Form A
6.2 Malfunctions
If malfunctions occur, check whether:
• the device has been installed according to the instructions,
• the electrical and fluid connections are correct,
• the device is not damaged,
• all screws have been tightened,
• the voltage and pressure have been switched on,
• the pipelines are clean,
• the power supply is adequately high.
Possible cause if the valve does not switch:
• Short circuit or coil interrupted.
• Inadequate power supply.
• Core or core area dirty.
• Medium pressure outside the permitted pressure range.
Possible cause if the valve does not close:
• Internal space of the valve is dirty.
english

7.2 Overview of spare parts

Type 0404
1
Type 0404, 5404
Seal
max. 1 Nm
Type 5404
1
2
2
3
9
3