Maintenance, Troubleshooting; Overview Of Spare Parts; Ordering Spare Parts; Transport, Storage, Disposal - Burkert 0280 Manuel D'utilisation

Électrovanne 2/2 voies
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6

MainTenance, TrOuBleshOOTing

6.1 safety instructions
Danger!
Risk of injury from high pressure in the equipment!
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
Warning!
Risk of injury from improper maintenance!
▶ Maintenance may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
8
7
spare parTs
Caution!
Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries and
damage the device and the surrounding area.
▶ Use only original accessories and original spare parts from Bürkert.

7.1 Ordering spare parts

Order the spare parts set SET 3 or coil set quoting the identification
number of the device.
8

TranspOrT, sTOrage, dispOsal

note!
Transport damages!
Inadequately protected equipment may be damaged during
transport.
• During transportation protect the device against wet and dirt in
shock-resistant packaging.
• Avoid exceeding or dropping below the allowable storage
temperature.
Incorrect storage may damage the device.
• Store the device in a dry and dust-free location!
• Storage temperature -40 ... +80 °C.
Damage to the environment caused by device components con-
taminated with media.
• Dispose of the device and packaging in an environmentally friendly
manner.
• Observe applicable regulations on disposal and the environment.
10
english
english
6.2 Malfunctions
If malfunctions occur, check whether:
• the device has been installed according to the instructions,
• the electrical and fluid connections are correct,
• the device is not damaged,
• all screws have been tightened,
• the voltage and pressure have been switched on,
• the pipelines are clean.
Malfunction
Valve does not switch
Short-circuit or coil interrupted
Medium pressure outside the permitted
pressure range
Core / core area is dirty
Flow restrictor hole in diaphragm dirty
Valve does not close
Internal space of the valve is dirty

7.2 Overview of spare parts

DN 13
Coil set
Spare parts set
SET 3
english
Type 0280
Possible cause
DN 8
9

Publicité

Table des Matières
loading

Table des Matières