6. Warning and Error Messages
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the
connection between battery and output or voluntarily disconnecting
the charge lead during the operation of charge or discharge on
output.
There was a short-circuit at the output. Please check the charging
leads.
The voltage of input power drops below the limit.
The voltage of the Lithium battery pack was selected incorrectly.
Verify the voltage of the battery pack carefully.
There happens a malfunction at the charger circuit by any reason.
The processor detects the voltage is lower than you set at the Lithium
program. Please check the cell count of the battery pack.
The processor detects the voltage is higher than you set at the Lithium
program. Please check the cell count of the battery pack.
The voltage of one of the cells in the Lithium battery pack is too low.
Please check the voltage of the cells one by one.
The voltage of one of the cells in the Lithium battery pack is too high.
P1ease check the voltage of the cells one by one.
There are bad connections at the individual connector. Please check
the connectors and cables carefully.
The internal temperature of the unit goes too high. Cool down the
unit.
The processor can not continue to control the feeding current by any
reason. The unit needs to be repaired.
13
Intelligent Digital Balance Charger xMove 2.0 Station