11. Warning and Error Messages
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the
connection between the battery and the output, or voluntarily
disconnection of the charge lead during the operation of charge or
discharge.
There was a shortcircuit at output. Please check the charging leads.
The voltage of input power drops out of the limit.
The processor detects the voltage is lower than you set at the
Lithium program. Please check the cell count of the battery pack.
The voltage of one of the cells in the lithium battery pack is too low.
Please check the voltage of the cell one by one.
The processor detects the voltage is higher than you set at the
Lithium program. Please check the cell count of the battery pack.
The voltage of one of the cells in the Lithium battery pack is too
high. Please check the voltage of the cells one by one.
In the process of charging, the battery connection breaked off.
In balance charge mode, the balance port connection breaked off.
6