5.5 Pb battery program
5.5.1 Charging Pb batteries
5.5.2 Discharging Pb batteries
5.6 Save data and load data program
5.6.1 Save data
Intelligent Digital Balance Charger xMove 2.0 Station
This is programmed for charging Pb batteries with nominal voltage
from 2 to 24 V. Pb batteries can not be charged rapidly. They can
only deliver relatively lower current compared to their capacity. The
optimal charge current will be 1/10 of the capacity. Please always
follow the instructions supplied by the manufacturer of battery.
As you can see on left, you can set up the charge current on the left.
The nominal of the second line and voltage of the battery on the right
of the second line. The charge current ranges from 0.1 – 10.O A and
the voltage should be matched with the battery being charged. Start
the charge process by pressing the "Enter/Start" key for more than
2 seconds.
The screen displays the state of charging process. To stop charging
forcibly, press "Mode/Esc" key once.
Set discharge current on the left and final voltage on the right, the
discharge current ranges from 0.1 – 5.O A and the voltage should
be matched with the battery being discharged. Start the discharge
process by pressing "Enter/Start" key for more than 2 seconds.
The screen displays the current state of discharge.
This charger can store/load up to 5 data of batteries, you can call out
the data for the process without setting up the program again.
Press the "Mode/Esc" key to the screen on the left, then press the
"Enter/Start" key to enter into the submenu.
The blinking (01) shows you the data (N0), you can press
"Dec </> Inc" key to change it. Press "Dec </> Inc" key, and you
can select the type of battery, voltage, capacity, and you can set them
by pressing the "Enter/Start" key for more than 2 seconds to select
the charge mode.
Setting up charge/discharge current and final voltage.
To save the data, press "Enter/Start" key for more than 2 seconds.
11