5.2 Initial parameter setup
Tips: Please set up correctly in the "User set" menu before you use it
for charging or discharging for the first time.
Press "Enter/Start" key to the first screen on the left, then press
"Mode/Esc" key to enter the into the parameter setting menu.
You can switched at the same level menu by "Dec. >"/ "Inc. <" key.
Please refer to the detailed flow chart on the left.
When you are willing to alter the parameter value in the program,
press "Enter/Start" key to make it blink, then change the value with
"Dec. >/Inc. <" key. The value will be stored by pressing the "Enter/
Start" key once.
This charger can accept three types of Lithium batteries: LiPo, Lilo
and LiFe.
You have to check the battery carefully and set it up correctly,
otherwise it will cause an explosion!
Please refer to table A.
The charger can recognise the cell count of Lithium batteries
automatically at the beginning of the charge or discharge process,
to avoid from erroneous setting by the user. But deeply discharged
batteries can be perceived incorrectly. To prevent this error, you can
set the time term to verify the cell count by the processor. (See the
screen
)
A0
Normally, 10 minutes are enough to perceive it correctly. For batteries
of larger capacity, you may extend the time term. And for batteries of
smaller capacity, you may reduce the term or use it with the default
value.
and
shows the trigger voltage for automatic charge
A1
A2
termination of NiMH and NiCd batteries (∆ V). The effective value
ranges from 5 to 20 mV per cell. lf ∆ V is set higer, there is a danger
of overcharging the battery; if lt is set lower, there is a possibility of
premature termination. Please refer to the technical specification of
the battery. (NiCd 12 mV, NiMH 7 mV).
Tip: lf the voltage of the charging battery is lower than
2.5 V, ∆ V may not be perceived. This will cause a danger of
discharge. You can connect a temperature sensor or use the
charger current above 1 C to avoid it.
There is a 3-pin port on the left side of the unit. lt can be used as
a temperature sensor port or USB port. lf the port is assigned as a
temperature port, you can use an optional temperature probe to
contact the surface of battery (see the screen
).
A3
5
Intelligent Digital Balance Charger xMove 2.0 Station