5.4 NIMH/NiCd battery program

5.4.1
After checking all the modes, to start the process press Enter/Start key
for more than 2 seconds
10
Press "Mode/Esc" key to the screen on the left, then press "Enter/
Start" key to get into the submenu. You can switch at the same level
menu to select the mode by "Dec </> Inc" key. Please refer to the
detailed flow chart on the left. When you are willing to alter the
parameter value in the program, press "Enter/Start" key to make it
blink. Then change the value with the "Dec </> Inc" key. The value
will be stored by pressing the "Enter/Start" key for more than 2
seconds to start the process. Since the menu of NiMH are the same as
NiCd, there is an example of NiMH only.
"CHARGE" mode: The default mode is "AUT". In "AUT" mode, you
need to set the upper limit of the charge current to avoid from higher
feeding current that may damage the battery. Because some batteries
of low impedance and small capacity can lead to the higher charge
current by the processor at automatic charge mode. But in "Man"
mode, it will charge the battery with the charge current you set at
the display. Each mode can be switched by pressing "Start/Enter"
key. When the current field is blinking, press "Dec. </Inc. >" key for
more than 1 second.
"DISCHARGE" mode: The discharge current ranges from O.1 A to
5.O A. And the final voltage ranges from 0.1 to 25.O V. The operating
method is similar as Lithium battery. The final voltage of a NiMH
battery is 1.O V/cell, and of a NiCd is 0.85 V/cell, please refer to the
recommended values by the battery manufacturer.
"CYCLE" mode: This charger can perform 15 cycles of DCHG > CHG or
CHG > DCHG continually. You can select it for the new Ni** battery or
the long-term placement Ni** battery.
Please set up carefully, or it will damage the battery!
To set the parameter please follow the previous charge/discharge
menu.
This screen displays the present state of process. To stop it press the
"Mode/Esc" key.
Description:
➀ Type of battery
➁ Operating mode:
CHG = charge
DSC = discharge
DCHG > CHG or CHG > DCHG = the cycle mode
➂ Elapsed time
➃ Charge/discharge current of the battery
➄ Voltage of the battery pack
➅ Capacity of charge/discharge
You can inquire the temperature and ∆ V continuaIly by pressing