Electrical connection
Pilot valve Type 6106:
•
Read the voltage, power rating and type of protection and current
from the nameplate!
•
Voltage tolerance: ±10 %
•
Use 10 mm filter to assure a long service life of the pilot valve!
•
Electrical connection: cable connector Type 2506 onto the plug
connector of the coil (fixing torque: 0.4 Nm)
•
Protection Type IP65 (only in connection with cable connector Type
2506).
•
The cable connector may be mounted turned by 180° to suit the cable
direction.
The coil heats up in operation!
NOTE
ATTENTION!
Observe the voltage: with AC be sure to
use the cable connector Type 2506 or
connect a rectifier between!
On screwing the cable connector to the
coil, make sure the flat seal is properly
seated!
Example
10 µm
Alwys connect the
protective conductor!
flat seal
T
D
ECHNICAL
ATA
0,4 Nm
Type 2506
8640-0450 - 9