5.6. User training

Train all users in how to use this motorised door safely (standard use and
locking principle) and in the mandatory periodic checks.

6. CONNECTING PERIPHERALS

Warning
The connection operations must be performed with the power off.

6.1. General wiring diagram - Fig. 21

Terminals
Connection
1
L
230 V power supply
2
N
3
Aux
Area lighting
4
Dry contact
5
Flash
24 V - 15 W orange
light output
6
7
-
24 V accessories
power supply
8
+
9
Tx
Power supply for pho-
toelectric cell trans-
mitter for auto-test
10
Batt
Battery
11
12
Start
Complete opening
control input
13
Common
14
Stop
Gate contact
15
16
Not used
17
Common
18
Cell
Cell safety input
19
Ant
Antenna earth
20
Antenna core
7
Comments
Max. 230 V - 500 W
• either 5 fluocompact or
LED lights
• or 2 power supplies for
low-voltage LEDs
• or 1 halogen light, max.
500 W
Compatible with 9.6 V
battery
NO dry contact
NO dry contact
NO dry contact

6.2. Description of the various peripherals

6.2.1. Photoelectric cells - Fig. 22
Carry out the following operations:
NB
The order of these operations must be complied with.
1) Remove the bridge between terminals 17 and 18.
2) Connect the cells
Fig. 22A - without auto-test
Fig. 22B - BUS
Fig. 22C - with auto-test
Allows an automatic test to be carried out to check the operation of the
photoelectric cells each time the door moves.
3) Program parameter P4.
without auto-test: "P4" = 1
BUS: "P4" = 2
with auto-test: "P4" = 3
Warning
It is compulsory to install photoelectric cells WITH AUTO-TEST P4
= 3 if:
• remote control of the mechanism is used when the door is not
visible,
• automatic closing is activated ("P0" = 2 or 3).
4) In the case of BUS cells, perform drive auto-programming again.
6.2.2. Reflex photoelectric cell - Fig. 23
Program parameter "P4" = 1.
6.2.3. Orange light - Fig. 24
6.2.4. Videophone - Fig. 25
6.2.5. Antenna - Fig. 26
Connect the antenna cable to terminals 19 (braid) and 20 (core).
6.2.6. Gate contact - Fig. 27
6.2.7. 9.6 V battery - Fig. 28
Degraded operation: speed reduced and constant (no slowing at end limit),
24 V accessories inactive (including cells).
Battery life: 3 cycles/24 hrs
6.2.8. Area lighting - Fig. 29
For class I lighting, connect the earth wire to the earth terminal on the
base.
NB
The earth wire must always be longer than the live and neutral
wires in case of detachment.
The lighting output must be protected by a 5 A time-delay fuse (not
supplied).
Lighting output power:
• either 5 fluocompact or LED lights
• or 2 power supplies for low-voltage LEDs
• or 1 halogen light, max. 500 W