Ph Or Redox Probe Faults (Ees Pro Only); Ph Or Redox Circuit Board Fault (Ees Pro Only); Maintenance - Procopi Label Bleu ESS Notice D'installation Et Conseils D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Calibrate the Redox probe
Wait for the Chlorine concentration to fall
and to see if the phenomenon reoccurs.
ORP LOW: this message is displayed when the
value measured by the Redox probe is less than
525 mV.
If no previous event explains this situation, try to
resolve the problem by carrying out the following
steps in the order indicated (if the problem is not
resolved by one step, proceed with the next):
Make sure that the Redox set point value is
correct.
Check that the probe is clean and
undamaged.
Using a recently calibrated photometer,
measure the concentration of free Chlorine in
the pool water to see if this value corresponds

PH OR REDOX PROBE FAULTS (EES PRO ONLY)

PH PROBE: pH probe not detected.
ORP PROBE: Redox probe not detected.
Cut power to the electrical/ control panel,
open the connection terminal compartment
and check that the two probes are properly
connected at the correct positions on the PCB.
Remove the probe PCB from its housing
PH/REDOX CIRCUIT BOARD FAULT (EES PRO ONLY)
NO CARD probe connection board not detected.
Cut power to the electrical/ control panel,
open the connection terminal compartment.
X.

MAINTENANCE

MAINTENANCE OF PH AND REDOX PROBES (EES PRO ONLY)
During use, scale may build up on the pH and
Redox probes, or a greasy deposit may accumulate
on their tips. This may be the case if their response
times are getting longer.
The probes should be removed from their mounting
tee and inspected at regular intervals (irst make
sure that the by-pass loop inlet and outlet shut-off
valves are closed, and place a bucket under the tee
to collect any water).
with the (abnormally low) Redox potential
displayed.
Calibrate the Redox probe
Check that iltration is running for long
enough each day (at least 10 hours a day
during the pool season)
Visually inspect the cell to verify that it is
producing and that the electrodes are not
covered in scale.
Check the stabiliser (Isocyanuric acid)
concentration in the pool. It should be between
30 and 50 mg/l
Increase the concentration of free Chlorine
and wait to see if this phenomenon reoccurs.
All these alarms are automatically reset when the
parameter returns to within an acceptable range.
and check that the pins are clean and in good
condition. Reinsert it fully into its housing.
Inspect the entire length of the wires of
each probe and make sure that they are not
damaged.
Close the by-pass loop shut-off valves and
remove the probes to check them for damage.
Remove the probe PCB from its housing
and check that the pins are clean and in good
condition. Reinsert it fully into its housing.
2015/02 - Indice de révision : B - Code : 29650
49/84