The Redox set point may be modiied within the
range 550 – 900 mV.
To do this:
Press the
button once: the current Redox set
point will be displayed.
To modify this value, press the arrow keys▲and▼
until the desired value is displayed.
To validate the new value and exit setting mode,
press the
button once.
1: An increase of the Redox set
Nota bene
point will cause an increase of the free Chlorine
concentration in the pool, while decreasing the
Redox set point will entail a decrease of the free
Chlorine concentration.
2: The correlation between the Redox
Nota bene
potential and the desired free Chlorine concentration
should be re-established:
Each year when the pool is reopened, if the pool

TURBO MODE

The Turbo
function allows continual
production of Chlorine at maximum output
(100%) over a duration set by the user.
Press the
button to switch to Turbo
mode: the word Turbo blinks at the bottom
of the output scale.
The Turbo mode duration is set to
EXAMPLE:
To activate Turbo mode for a duration of 26 hours
and 30 minutes. After having activated Turbo mode,
press the T button once -> 24:00 is displayed. To set
the minutes, keep the ▲ key pressed down (rapid
scroll) and then press successively until 26:30 is
displayed. If the value is overshot, use the ▼ key
to return to the desired value.
Next, the displayed time will start to count down,
this represents the time remaining for the Turbo
cycle.
Nota bene
1: begin setting the duration of the Turbo
cycle with the T button within 5 seconds of entering
Turbo mode. Each successive press on the T button
to modify the length of the cycle must occur within

COVER MODE

This mode concerns pools equipped with a cover
and a system that detects when the cover is
deployed over the pool and closes a dry contact.
This is mainly useful for pools itted with the EES
44/84
2015/02 - Indice de révision : B - Code : 29650
was winterized
if a signiicant volume of the pool water (more
than 1/3) is renewed
if a decision to alter the stabiliser concentration
is made
To do this you will need a photometer capable of
measuring the Chlorine concentration with adequate
precision, and that has been calibrated within the
last year; if necessary adjust the concentration by
adding small amounts of Chlorine successively,
until the required concentration is reached. Note
the Redox potential measured by EES Pro, this is
the set point. If a regular drift from the Redox value
is noticed, or if there is a sudden change in this
value, replace the Redox probe.
3: The Redox system does not allow
Nota bene
precise regulation of the free Chlorine concentration
at high set point values (above 2 ppm, that is
approximately 725 mV at pH = 7.4).
12 hours in the factory, this setting is
displayed on screen.
Successive presses on the T button will
increase the duration in increments of
12 hours up to a maximum duration of
72 hours (then returns to 0).
For iner adjustment, in intervals of one
minute, use the arrow keys, ▲ and ▼.
5 seconds of the last. Otherwise, pressing the T
button will cause the device to exit Turbo mode.
There are 3 ways to exit Turbo mode:
allow more than 5 seconds to elapse and then
press the T button.
stop the device using the ON/OFF button
set the duration of the cycle to 00 : 00
Neither activation nor exiting Turbo mode will effect
settings in AUTO mode.
Nota bene
2: Even in Turbo mode, the device will not
run with an output of 100% if the salt concentration
in the water is too low. It will run at its highest
possible output for the current concentration of salt
in the water.
model because this model does not regulate the
concentration of Chlorine in the water but rather
produces Chlorine for as long as the iltration cycle
is running. While the cover is deployed over the
pool, the free Chlorine is protected from destruction