Respect the direction of low of water (red arrow)
through the low detector.
If the low detector is mounted horizontally, the
blue head must be oriented upwards (otherwise
impurities can gather in the mechanism and prevent
correct operation)
LOCATION OF EES PRO PH AND REDOX PROBES:
Ideally, the pH and Redox probes should be mounted
on a by-pass loop located between the pump
and the ilter to ensure that the values measured
are representative. In fact, if it is contaminated with
organic pollutants, the ilter can modify the Redox
and pH values of the water lowing though it.
The probes should be mounted upstream of any
heating system: temperature changes will modify
the pH and Redox values.
To prevent damage to the probes by gravel or sand,
the by-pass valves should be adjusted so that the
low past the probes is slow.
To prevent static and interference, probe cables
should not be run in the same sheaths as the other
PRECAUTIONS CONCERNING THE PROBES:
THE SUBMERGED SECTIONS OF THE PROBE:
must always be immersed inpool water or tap
water, even when not in use (this point only
concerns the pH probe)
must never be touched with ingers
THE PH AND REDOX PROBES MUST BE CALIBRATED:
Upon reopening the pool
Every four to twelve weeks depending on the
bather load
36/84
2015/02 - Indice de révision : B - Code : 29650
faible.
Les câbles des sondes ne doivent pas être regroupés dans des gaines avec d'autres câbles
electrical cables.
The probe mounting tee should be mounted on a
i
horizontal section of the by-pass loop, and oriented
such that the pH probe is vertical. Nevertheless,
i
the probes should not be located at a high
i
point on the hydraulic circuit so that they will
remain immersed in water even if air enters the
i
hydraulic circuit.
must never be wiped
must not be allowed to be caught in ice
must be descaled when necessary
i
i
i
i