CHLORINE STABILISATION:

The Chlorine introduced into the pool by the
electrolysis cell is unstabilised active Chlorine that
is easily destroyed by UV light and heat.
To limit this phenomenon while the pool is
uncovered, the addition of a Chlorine stabiliser,
Isocyanuric acid (concentration approx. 30 ppm) is
recommended.
VII.
STARTING THE ELECTROLYSER:
Once the electrolyser is wired in, hydraulic
connections have been made, the water parameters
have been adjusted and the salt and stabiliser have
been completely dissolved, the device may be
switched on.
1)
Upon being energised, the message OFF is
displayed on the LCD screen. Press the ON/OFF
button (7).
If the low of water past the low detector is
adequate (> 5 m3/h), the message ON (EES) or
AUTO (EES Pro - indicating that production of
Chlorine is controlled by the pH and Redox probes)
is displayed at the bottom of the LCD screen: the
device is able to produce Chlorine.
If the message STD-BY (stand-by) is shown, the
iltration timer is not currently at a run cycle: check
that the timer is in Auto mode and wait for the next
iltration cycle, or force iltration on by switching the
timer to the I position.
42/84
2015/02 - Indice de révision : B - Code : 29650
The Chlorine stabiliser does not break down over
time; if the pool was disinfected with Chlorine
before the electrolyser was installed, measure the
initial stabiliser concentration before adding any
more. Excess stabiliser (above 75 ppm) will block
the action of Chlorine and falsify measurement of
the Redox potential.
If the timer triggers the iltration pump to run, but
the water low rate is too low (< 3 m3) or there is no
low, the message NO FLOW is displayed. Check
the following:
the iltration pump is running
the pump is properly primed
the pump is rotating in the correct direction (in the
case of a 3 phase pump)
The valves on the by-pass loop are correctly
adjusted: the central valve is suficiently closed
and the 2 valves upstream and downstream of
the EES electrolyser are suficiently open;
water is lowing in the correct direction past the
low detector, and the low detector has not been
mounted upside down
the low detector is correctly connected to the
EES control panel
Disconnect the low detector and using an
ohmmeter check the continuity of the 2 connector
contacts while water is circulating.
When production is possible (ON for EES, AUTO
for EES Pro), the device begins by measuring
water salinity, this value is displayed 1 minute
after the device starts up. After this delay, if the
salt concentration is within acceptable limits,
the production of Chlorine begins and gradually
increases. Upon reaching the required level, the
bar under Output % stops blinking and disappears.