SAFETY RECOMMENDATIONS:

USER SAFETY

The EES and EES Pro electrical/ control panel
should be wired in by a qualiied professional,
according to the standards in effect in the country
of installation. It should be located at least 3.5 m
from the pool.
Should this be impossible, it may be positioned
closer than 3.5 metres, but not less than 2 m from
the pool (the control panel has a protection rating
of IP56, against splashing), subject to the condition
that the power cable is connected directly to a 30
mA residual circuit device.
Never remove the cover protecting the electrical
panel connection terminals while the electrical
panel is energised. Always cut the power supply to
the electrical panel beforehand. The cover should
be replaced immediately after the intervention.
In the event of damage to the power cable, have it
replaced immediately by a professional.
Locate the electrical/ control panel high enough to
be out of the reach of children.
SAFETY OF MATERIALS AND PREMISES:
The electrical/ control panel power cable must
be protected by a suitably rated thermo magnetic
circuit breaker.
Never operate the device by electrically bypassing
the low detector. If no water is lowing through the
cell, there is a risk that inlammable vapours could
accumulate in the pool's hydraulic circuit.
Never operate the device while the hydraulic circuit

LOCKING/ UNLOCKING THE KEY PAD :

The electrolyser's electrical/ control panel key
pad can be locked to prevent any manipulation by
unauthorised personnel.
To lock the key pad: press the
simultaneously until the
To unlock the key pad, press the same keys
32/84
2015/02 - Indice de révision : B - Code : 29650
key and ▼ key
icon appears.
Nota bene:
The electrolyser cell is powered by
a 12V direct current supply from the electrical/
control panel. There is therefore no electrical risks
to bathers using the pool while the device is in
operation.
Safety recommendations concerning the
pH Clear pump:
The
pH-Clear
pump
concentrated acid into the hydraulic circuit.
When handling acid, and during interventions on
the pump or its tubing, protective glasses and
clothing should be worn to protect against splashes.
In the event of contact with the skin, lush the area
abundantly with water, seek medical attention
immediately if the eyes are effected.
Check the condition of the tubing through which the
acid lows regularly and replace it immediately if it
appears worn or damaged or is leaking.
upstream and downstream from the device is
blocked. Vapours accumulating in the cell could
cause an overpressure leading to the rupture of the
cell.
Be careful of freezing temperatures! Like other
hydraulic equipment, the cell, the low detector, the
pump and the sensors are very sensitive to icing.
Ensure that the temperature in the plant room is
always above zero to prevent this type of damage.