with quick it connectors (cable length approx. 3.60
m). The two tabs keep each pair of connectors
correctly assembled with respect to each other.
Check that they are irmly connected by pulling
lightly on each connector.
NEVER MODIFY, SHORTEN OR LENGTHEN
THE CABLES.
WIRING IN THE CONTROL PANEL :
Principal: production of Chlorine by the cell must be slaved to operation of the iltration pump and
circulation of water through the low detector.
Disjoncteur magnéto-
Magnetotheral circuit breaker,
pump
thermique pompe
N/LN1 = permanent neutral
LN2 = permanent live (panel and pH-Clear)
LD2 = slaved live (cell)
*Nota bene: to avoid electrical disturbances when the pump starts and stops, the EES power cables
should not be in contact with those of the iltration pump: use a contactor with 4 power inputs/ outputs
as illustrated in the diagram, or failing this a contactor with 2 power inputs/ outputs for the pump and
a relay for the EES, both slaved to the iltration timer.
The power rating of the panels are as follows:
Panels for pools up to 80 m3 = 0.6 A
Panels for pools up to 150 m3 = 1.2 A
To connect the control panel to the contactor and the contactor to the mains, we recommend that you
use cables with a strand cross section of 1.5 mm
section of 2.5 mm
2
.
40/84
2015/02 - Indice de révision : B - Code : 29650
230 V ~
Contacteur*
Switch*
2
. If the cable is very long, use one with a strand cross
Disjoncteur, porte-
Circuit breaker, fuse housing or switch
fusible, ou secionneur
Bornier alimentaion
EES panel power supply terminal
coffret EES
Horloge
Timer
Auto