5A - DIP-SWITCH 1 - MODE
If the "MODE" dip-switch is set to ON, the control unit is set on slow mode.
This mode is fit for wings longer than 2 m.
If the "MODE" dip-switch is set to OFF, the control unit is set on slow mode. Anyway, it is suggested to pay attention on the
wings can't hurt too violently against the mechanical stop; otherwise, the gate and the mechanics of the operator could be
damaged.
5B - DIP-SWITCH 2 - STEP
If the "STEP" dip-switch is set to ON, the step-by-step function is enabled. Every time the control unit receives an input signal, it
perform an action. When the automation is stationary, it starts the motor, and when the automation is moving, it stops the motor.
If the "STEP" dip-switch is set to OFF, the modality OPEN/STOP/CLOSING is enabled. The control unit accepts only commands
(by wire or by transmitter) in opening. So, when the gate is closed, it opens. When the gate is opening, it keeps opening, and
when the gate is closing, it opens completely.
The reclosing takes place with the time set by the "PAU" trimmer, if the "AUTO" dip is set to ON.
Otherwise, it is necessary to give a START command (by wire or by transmitter).
5C - DIP-SWITCH 3 - AUTO
If the "AUTO" dip-switch is set to ON, the automatic reclosing function is enabled. The control unit automatically closes the
wings after the time set by the "PAU" trimmer (see paragraph 4B).
If the "AUTO" dip-switch is set to OFF, the automatic reclosing function is disabled. It is necessary to supply a command (by
wire or by transmitter) to close the wings.
5D - DIP-SWITCH 4 - PHO2
If the "PHO2" dip-switch is set to ON, the safety devices in opening and closing, when they intervene, stop the motion of the
wings, which will open again as soon as cleared (typical functioning of the photocell).
If the "PHO2" dip-switch is set to OFF, the safety devices in opening, when they intervene, invert the motion for 2 seconds, and
then they stop the automation. So, it is necessary to supply a command (by wire or by transmitter) to finish the travel, and close
the wings (typical functioning of the safety edge). With this setting these safety devices in closing do not intervene.
5E - DIP-SWITCH 5 - LAMP
If the "LAMP" dip-switch is set to ON, the power supply given to the lamp (terminals 8,9) is intermittent (see paragraph 12A).
If the "LAMP" dip-switch is set to OFF, the power supply given to the lamp (terminals 8,9) is direct (see paragraph 12A).
5F - DIP-SWITCH 6 - STRIKE
If the "STRIKE" dip-switch is set to ON, the kick-back is enabled (see paragraph 12D). In this way, the control unit will supply a
voltage swing at the beginning of the opening cycle, and at the end of the closing cycle.
If the "STRIKE" dip-switch is set to OFF, the kick-back is disabled.
5G - DIP-SWITCH 7 - FAST
If the "FAST" dip-switch is set to ON, the rapid reclosing is enabled. This modality enables to reclose the gate as soon as the
control unit notices that the photocell range have been occupied and cleared. So, going through the passage, the automatic
reclosing of the automation will be enabled, without waiting the pause time.
If the "FAST" dip-switch is set to OFF, the automatic reclosing is disabled
5H - DIP-SWITCH 8 - RADIO
If the "RADIO" dip-switch is set to ON, the START channel is memorized during the programming of the radio transmitter (see
paragraph 3).
If the "RADIO" dip-switch is set to OFF, the pedestrian opening channel is memorized during the programming of the radio
transmitter (see paragraph 3).
5 - DIP-SWITCHES DESCRIPTION
(see also paragraph 11B)
(see also paragraph 12A)
(see also paragraph 12D)