Main Features; Technical Data - Aprimatic Flexi 300EL Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1B - STARTING MODALITY
The control unit has been designed to manage 1 or 2 24Vdc motors gate automations.
To start the system it is necessary to:
1- Connect the power supply, the motors, and the accessories as indicated in the 2nd paragraph
2- Set the dip-switches (paragraph 4A) and the trimmers (paragraph 4B) depending on the wanted functioning and on the
conditions of the system.
3- Perform the standard programming procedure (paragraph 6B) or the professional programming procedure (paragraph 6D), to
recognize the starting point and the end point of the travel.
4- Perform the checks reported on paragraph 6C (warning before starting).
If the control unit keeps on having problems after these steps, see paragraph 9 "Signaling led", to identify possible
!
anomalies, and paragraph 14 "inconvenient and remedy" to try to eliminate them.
1C - MAIN FEATURES
- Management and control for 1 or 2 24Vdc motors (terminals 24,25,26,27).
- Double opening-closing limit switch inputs (terminals 3,4,5,6,7).
- 433.920Mhz rolling code built-in receiver (code: "RX STAR", see paragraph 1A – 13B).
- Removable memory (code: "MEMO") containing up to 180 memorized radio codes (paragraph 1A - 13A).
- 6 signaling led (paragraph 1A – 9).
- Predisposition for the 12 Vdc card for electric lock control connection (max 15W, optional) (see paragraph 12D).
- Predisposition for the battery charge card and the 24Vdc batteries up to 7Ah (optional) (see paragraph 12E).
- Predisposition for the 230 Vac card for courtesy light control connection (max 500W, optional) (see paragraph 12F).
- Customizable and differentiable slow down in opening and closing thanks to the professional learning procedure (see paragra-
ph 6D).
- The control unit "Flexi 300EL" has got a "backjump" (an impulse to the motor at the end of opening and closing, in order to
loosen the mechanism, and make the manual release easier.
- Built-in lamp intermittent manager (see paragraph 12A).
- Customizable pedestrian opening by pedestrian programming procedure (see paragraph 7).
- Customizable delay between the wings in closing from 0 to 15 sec. by trimmer (see paragraph 4B).
- Pause time before automatic reclosing customizable from 0 to 90 sec. by trimmer (see paragraph 4B).
- Sensibility of the intervention adjustable from 0.1 to 3 sec. by trimmer (see paragraph 4B).
- Power/speed adjustable from 50% to 100% by trimmer (see paragraph 4B).
- Input for control-by-wire to manage start, stop and pedestrian opening.
- Double safety inputs: closing (terminal 16) and opening and closing (terminal 17).
- Input for warning light to signal the wings position (see paragraph 12C).
1D - TECHNICAL DATA
Control unit supply
Motor output
Primary transformer
Secondary 1 transformer
Secondary 2 transformer
Transformer power
Photocells output
Flashing lamp output (Terminals 8,9)
Open gate warning light output (Terminals 18,20)
Working temperature
1E - PRESETS
If you perform the standard programming procedure (see paragraph 6B), and there are no modifications on the trimmer regula-
tion (see paragraph 4B) and on dip switches (see paragraph 4A), the control unit will act as follows:
- The safety devices in closing, connected to "PHO1" contact (terminal 16), will intervene only in closing, inverting the motion.
- The safety devices in opening, connected to "PHO2" contact (terminal 17), will intervene both in closing and in opening,
keeping on the motion when the device has been cleared (setting by the dip 4 "PHO2").
- Activation of electric limit switches management (terminals 3,4,5,6,7) only if they are connected. If there are no electric limit
switches, the terminals must be free.
- Pause time before automatic reclosing equal to 45 seconds.
- Operating mode set for fast working (modality settable by "MODE" dip).
- Pedestrian opening procedure controlled by cable and by transmittter (if the transmitter has been programmed by the
procedure as per paragraph 3b) and with total wing opening operated by MOT1 (terminals 24, 25).
- The slowdowns are set to the final 15% of the travel.
230 Vac
24 Vdc (Maximum 60Watt per motor)
230 Vac
12 Vdc
24 Vdc
150Va
12 Vdc, max 15W, protected by fuse
24 Vdc, max 15W, protected by fuse
12 Vdc, max 3W, protected by fuse
-20 ÷ +55

Publicité

Table des Matières
loading

Table des Matières