1. INTRODUCTION

The control unit denominated
encoder input for learning the stroke and recognising the obstacle.
Thanks to the considerable amount of logic available even very particular operating conditions on sytems can be met.

2. MAIN FEATURES

- Microprocessor logic
- Green LEDS displaying the status of the N.O. control inputs and red LEDS for the status of the N.C. safety ones
- Pull out terminal blocks
- Output for flashing warning lamp and traffic light
J2
AP.PED
CHIUDI

3. TECHNICAL SPECIFICATIONS

- Power:..........................................................................................................230Vac ±10% 50/60 Hz 100W
- SCA output:.................................................................................................................................24Vac 3 W
- Flashing lamp output:.........................................................................................................24Vac 25Wmax
- Power supply output for accessories:.................................................................20 ÷ 26 Vac 12W max
- Installation and operation manual
is designed to manage the "
J1
APRI
START
- 11 -
" automatic barrier and is equipped with
M1:
Power terminal board
M2:
Controls and safety devices terminal board
M3:
Motor terminal, transformer, +acc
J1:
Selection Jumper - 1st radio channel
J2:
Selection Jumper - 2nd radio channel
SW3: 8-way Dip Switch
F2:
T1A 5x20
AP.PD: Semi-automatic opening cycle
START: Start and programming
PM1:
Pause time
PM2:
Speed
PM3:
Pre-manoeuvre warning lamp flash time