The Altrad Belle 'Vibratech' is designed to give many years of trouble free operation. It is, however, important that the simple regular
maintenance listed in this section is carried out.
It is recommended that an approved Altrad Belle dealer carries out all major maintenance and repairs. Always use genuine Altrad Belle
replacement parts, the use of spurious parts may void your warranty.
Because of various risks with regards to cleanliness we advise against washing and then applying new grease onto used and disman-
tled bearings during maintenance works and assembling them again. We recommend instead the use of original and new grooved ball
Service, connection and assembly may be accomplished only on the condition that:-
The electrical installation is dead.
Protected against reconnection.
All drives are in the STOP position.
In switch-on position, electrical installations and machinery contain live, naked wires or rotating parts. This could result in personal
injury and material damage should the covers and protection devices be removed contrary to regulations. This could also happen
under wrong handling and maintenance or misapplication. Dealing with devices equipped with power electronics the expert might
come accross another uncommon danger which so far he may not have encountered, i.e. the device still contains electrical voltage
even after the supply voltage has been cut off.
WARNING
During clamping work on the terminal board, the Poker must be dead.
According to EC standards concerning the electro-magnetic compatability, the electro-magnetic interferences are to be reduced by
Periodic Mantenance
3. In all maintenance operations, original parts will be used.
4. If you have replaced the switch, ensure the bolts are tightened and the box is watertight.
DIMENSIONS OF WEAR FOR DIAMETERS AND LENGTHS OF THE POKER
a. The minimum dimensions are printed in bold.
b. The dimensions in brackets are the original dimensions.
c. Replace the housing when it reaches the minimum diameter.
d. Replace the tip when it reaches the minimum length.
Service & Maintenance
Observe the waiting period before opening the 'Vibratech' Poker. In addition to the time of discharge,
which is about 90 seconds, wait and check for any residual voltage prior to starting work. The waiting
period is at least 2 minutes after the plug has been disconnected.
. Cable screening must be done on both sides.
B
A
Model
Diameter (mm)
38
52
58
11
Length (mm)
36.5
325
50.5
378
56.5
405