Menu "Settings"
Basic settings can be made here, e.g.
„ Connection to a Backend-System
„ Maximum charging current
If necessary the presets defined in the menu "> Default"
can be restored through the button "Settings Default &
Restart".
Menu"> Default"
This is where presets for the "Settings" menu can be
defined.
Menu "Operator"
This is where all advanced settings for setting up the
device can be made, e.g.
„ Connection to a Backend-System
Menu "System"
Here you cannot make any settings. Information concer-
ning the firmware Version and the system are displayed. A
firmware update can be executed here.
Menu "Documentation"
Here you cannot make any settings. The interface docu-
mentation and error messages are described.

6.2.1 Operating mode "Autostart"

The device is operated as a stand-alone solution without
connection to a Backend-System. An authorisation is not
required. Charging starts automatically as soon as the
vehicle is plugged in.
f Navigate to the "Settings" menu and set the following
parameters:
Parameters
Connection Type
Free Charging
f When the configuration is concluded, click the "Save &
Restart" button.
Setting
f Select "No Backend".
f Select "On".

6.2.2 "Local Whitelist" mode

The device is operated as a stand-alone solution without
connection to a master Backend-System. The authorisati-
on occurs through RFID cards and a Local Whitelist.
f Navigate to the "Settings" menu and set the following
parameters:
Parameters
Connection Type
Free Charging
If in doubt allow char-
ging
f Click the "Save" button.
f Navigate to the "Operator" menu and set the following
parameters:
Parameters
Setting
Local fixed
f Select "On".
authorization
list
List of entries
f Enter UIDs (Unique Identifiers) of the
in fixed local
RFID cards authorised to charge.
list (FLL)
„ To do this, the UIDs of the RFID cards
must be known.
„ The RFID UIDs are separated by a
colon.
„ A maximum of 80 RFID cards (UIDs)
can be programmed.
f When the configuration is concluded, click the "Save &
Restart" button.
Setting
f Select "No Backend".
f Select "Off".
f Select "Off".