Ensure the component is firmly attached.
–
Connect the 8-mm or 10-mm gas supply pipe to the
regulator outlet according to the respective installation in-
structions for olive screw connections (e.g. EN ISO 8434-1).
When tightening, carefully use a second spanner on the
provided spanner surfaces to keep the entire assembly from
turning.
–
Screw high-pressure hoses (only with HRP) to the
DuoControl CS inlets, using angle unions if necessary .
–
When the installation operation has been completed, arrange
for the entire gas system to be leak-tested and checked by a
specialist technician to ensure correct installation. Check the
hose connections at the DuoControl CS inlet for leaks (e.g.
using a leak finder spray in accordance with EN 14291). If a
gas testing certificate already exists it must be supplement-
ed / updated accordingly.
This test does not replace the regularly scheduled gas
check!
Sticker
The provided sticker must be affixed in the cylinder box.
Then all functions must be tested in accordance with the op-
erating instructions.
The operating instructions must be handed over to the vehicle
operator.
18
Manufacturer's terms of warranty
1. Case of warranty
The manufacturer grants a warranty for malfunctions in the
appliance which are based on material or production faults.
In addition to this, the statutory warranty claims against the
seller remain valid.
A claim under warranty shall not pertain:
–
for parts subject to wear and in cases of natural wear and
tear,
–
as a result of using components in the units that are not
original Truma parts,
–
as a result of damage caused by foreign substances (such
as oil, softener) in the gas,
–
as a consequence of failure to respect Truma instructions
for installation and use,
–
as a consequence of improper handling,
–
as a consequence of improper transport packing.