Individuelle Ringraumdichtung HRD
• knowledge of the waterproof concrete directive and building waterproofi ng
standards as amended.
General information and intended use
In line with their intended use, our products have been developed solely for instal-
lation in buildings made of state-of-the-art materials. Insofar as no express written
confi rmation has been provided by us, we do not accept any liability for any other
purposes or purposes going beyond the above.
The individual press seal HRD in closed or split design is suitable for gastight and wa-
tertight sealing of cables which are to be newly installed or have already been installed.
tertight sealing of cables which are to be newly installed or have already been installed.
Individual HRD press seals are tested by FHRK according to current test guidelines
and bear the seal "FHRK Quality".
Safety
This section provides an overview of all the main safety aspects for optimum
protection of personnel and a safe installation process.
If there is a failure to observe the instructions and safety information set out here,
this may result in signifi cant hazards.
When installing press seals HRD for cable and pipe connections, it is imperative to
observe the relevant professional association rules, the VDE provisions, the relevant
national safety and accident prevention regulations and your company's guidelines
(work and procedure instructions).
The fi tter must wear the relevant protective clothing.
Only intact components may be installed.
The following instructions are to be observed prior to installati-
on of the press seal HRD for cables and pipes:
on of the press seal HRD for cables and pipes:
WARNING!
Risk of injury in the event of improper installation!
Improper installation can result in signifi cant bodily harm and property damage.
• The nationally applicable laying and fi lling regulations for pipes and cables are
to be observed at all times.
• Seal the underground and pipe substructure well prior to laying pipes/cables
so that the latter cannot subside.
IMPORTANT!
No sealing due to incorrect installation!
Improper installation can result in damage.
• Pressed seals are not fi xed points or bearings and, as such, are unsuitable for
sustaining mechanical forces.
• Press seals are not fi xed settlement points or bearings and therefore cannot
absorb any mechanical forces. Any anticipated reductions must be compensated
for by the installation of centering guides in the conduits or core drillings
and/or by spacers.
• For the one-sided installation of the press seal and the sealing set ADS into the
core drilling, carry out the sealing on the outside of building.
• The inside of the wall sleeve must be clean and free of dust and grease.
• Cables may not have any continuous grooves in the sealing area (possibly push
cable back or forwards a little until grooves are no longer visible).
• Cables must be clean and free of soiling.
• Do not spread lubricant on the outer sealing surface of the press seal. The latter
must be clean, dry and free of grease.
• The nuts of the hexagonal bolts must be on the installation side of the press
seal HRD.
• Openings that are not used must be sealed with suitable plugs.
• With a permanent dynamic pressure, the press seal must be secured against
sliding out of the core drill hole/wall sleeve.
• The press seal must be secured against sliding out of the core drill hole/wall
sleeve before starting disassembly.
• Depressurise the core drill hole/wall sleeve.
• If the press seal is installed in an exposed duct, then the duct wall must be
stabilised with a clamping strap at the location of the press seal.
• For the one-sided installation of the press seal into the core drilling, carry out
the sealing on the outside of building.
• Any anticipated recesses must be compensated for by installing centring aids
or spacers in the wall sleeves or core drill holes.
• In the case of thin-walled or foamed pipes, only tighten the seals to a point at
which the pipes are not deformed.
• Deformed or damaged corrugated cable ducts are not suitable for sealing.
These must be cut off or replaced.
• No cleaning agents containing solvent may be used to clean the cable seal. We
recommend using cable cleaner KR M.T.X.
• For details of other accessories and further information, see www.hauff-technik.
de and the technical specifi cation sheets.
Personnel requirements
Qualifi cations
WARNING!
Risk of injury in case of inadequate qualifi cation!
Improper handling can result in signifi cant bodily harm and property damage.
• Installation may only be carried out by qualifi ed and trained individuals who have
read and understood these instructions.
Skilled experts
Based on their specialist training, skills, experience and familiarity with the relevant
provisions, standards and regulations, skilled experts are able to carry out the worked
assigned, independently identifying and avoiding potential hazards.
Transport, packaging, scope of delivery and storage
Safety instructions in connection with transport
Safety instructions in connection with transport
IMPORTANT!
Damage in the event of improper transport!
Signifi cant damage can occur in the event of improper transport .
• When unloading packaging items on delivery and in the course of in-house
transport, proceed with care and observe the symbols on the packaging.
Transport inspection
Inspect the delivery immediately on receipt for completeness and transport damage.
In the event of transport damage being visible from the outside, proceed as follows:
• Do not accept the delivery or only do so subject to reservations.
• Make a note of the extent of damage in the transport documentation or delivery
note provided by the transporter.
Delivery scope
The press seal HRD for cables and pipes is supplied with the following:
1 Press seal HRD
1 GM lubricating stick (Article number: 0804020000)
Storage
IMPORTANT!
Damage due to improper storage!
Signifi cant damage can occur in the event of improper storage.
Protect the press seal and the sealing set from damage, damp and soiling prior
to installation. Only intact components may be installed.
The press seal and the sealing set must be stored in such a way that it is
not exposed to low temperatures (<5° C), high temperatures (>30° C) or
direct sunlight.
Disposal
If no return or disposal agreement has been concluded, recycle dismantled
components after they have been properly dismantled:
• Metal remains are to be scrapped according to existing environmental
regulations.
• Dispose of elastomers according to existing environmental regulations.
• Dispose of plastics according to existing environmental regulations.
• Dispose of packaging material according to existing environmental regulations.
Consignes de sécurité et informations
Public
Ce montage peut être effectué uniquement par des personnes compétentes.
Les personnes qualifi ées et formées pour le montage
• ont connaissance des règles de sécurité et de prévention actuellement en vigueur,
• savent utiliser un équipement de sécurité,
• savent manier des outils manuels et électriques,
• ont connaissance des normes et directives actuellement en vigueur pour la pose
de tuyaux/câbles et pour le remplissage de tranchées,
• ont connaissance de la réglementation et des consignes actuellement en vigueur
des entreprises de fourniture en énergie,
• ont connaissance de la directive sur le béton WU et des normes sur l'étanche-
ment des ouvrages actuellement en vigueur.
Généralités et usage prévu
Nos produits sont, conformément à leur utilisation prévue, exclusivement mis au
point pour l'insertion dans les constructions dont les matériaux correspondent à
l'état actuel des techniques. Nous déclinons toute responsabilité pour une utilisa-
tion autre ou allant au-delà de l'usage prévue, si elles n'ont pas été confi rmées par
écrit après accord avec nous.
Les termes de la garantie sont précisés dans nos conditions de vente et livraison
actuelles.
Joint annulaire en caoutchouc spécifi que HRD, en version fermée ou divisée, pour
l'étanchéifi cation à l'eau et au gaz de câbles et tubes nouvellement installés ou
déjà posés.
déjà posés.
Art. Nr.: 5090032054
Rev.: 02/2019-11-18
• Submit a claim for every defect as soon as it has been identifi ed.
• Claims for damages can only be asserted within the applicable claim
period.
Les joints annulaires en caoutchouc HRD individuels sont testés par la FHRK selon
les directives en vigueur pour les essais et ils jouissent du label « FHRK Quality ».
FR
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hrd

Table des Matières