Logic
Definition
Open in other
OPEN IN OTHER
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
Configuration of
safety input SAFE 2.
SAFE 2
Configuration of
safety input SAFE 3.
SAFE 3
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
Configuration of
command input IC 3.
IC 3
Configuration of
command input IC 4.
IC 4
Configuration of
AUX 3 output.
AUX 3
Setting the
prot. l ev
protection level
30 -
LEO C
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
 
0
72
 
6
74
2
 
77
0
61
4
62
 
2
64
3
65
0
26-37
0
0
Standard operating mode
1
Opens in other direction to standard operating mode
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
9
Input configured as Bar op safety edge active only while opening
10
Input configured as Bar op test, safety edge tested as active only while opening
11
Input configured as Bar 8k2, safety edge 8k2 active only while opening
12
Input configured as Bar cl safety edge active only while closing
13
Input configured as Bar cl test, safety edge tested as active only while closing
14
Input configured as Bar 8k2 cl, safety edge 8k2 active only while closing
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
NOT AVAILABLE
9
Input configured as Bar op safety edge active only while opening
10
Input configured as Bar op test, safety edge tested as active only while opening
11
NOT AVAILABLE
12
Input configured as Bar cl safety edge active only while closing
13
Input configured as Bar cl test, safety edge tested as active only while closing
0
Input configured as Start E.
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light
5
Output configured as Alarm
6
Output configured as Flashing light
7
Output configured as Latch
8
Output configured as Magnetic lock
9
Output configured as Maintenance
10
Output configured as Flashing Light and Maintenance.
A - The password is not required to access the programming menus
0
E - The board's parameters can be edited via the U-link network
1
Not used
2
Not used
3
Not used
A - You are prompted to enter the password to access the programming menus
4
The default password is 1234.
E - The option of editing the board's parameters via the U-link network is disabled.