perma-tec GmbH & Co. KG
4.
Lubricator Exchange
At the end of a lubrication period, the red piston becomes clearly visible through the
cap, indicating the end of the discharge period (a small amount of lubricant might
remain in the perma CLASSIC).
Remove the empty lubricator and replace it with a new one (see chapt. 2).
Even a used perma CLASSIC can NEVER be opened.
5.
Trouble shooting
Malfunction
No lubrication
Discharge too
fast
Not enough
lubricant
chart 3
The World of Automatic Lubrication
Possible cause
no gas development
still within activation period
temperature/vibration too high
wrong activator screw
for oil fi lled lubricator:
no oil throttle installed
temperature too low
counter pressure too high
wrong activator screw
Solution
slightly shake perma
CLASSIC or slightly tap on the
activator screw (ring should
have broken off)
please observe "initial delay"
(see chapt. 3)
remote installation
(see chapt. 2 and 3)
new perma CLASSIC and
correct activator screw
for oil fi lled lubricators:
install oil throttle
contact your local perma
supplier
check lubrication point
new perma CLASSIC and
correct activator screw
- 10 -