INSTALLATION
INSTALLATION CONFIGURATION
INSTALLATION
5.
Installation confi guration
The Tempra can be used for the following applications.
1
Typical residential installation
1
2
2
Typical commercial installation
3
3
4
4
1
5
5
2
6
6
3
7
7
4
8
8
5
9
9
6
10
10
1
7
11
11
2
8
12
12
3
9
13
13
4
10
14
14
5
11
15
15
6
12
16
16
7
6.
Mounting the unit
13
17
17
8
14
18
NOTICE: Unit must be installed in a vertical position
18
9
!
15
19
with the water fi ttings pointing downward.
19
10
16
20
WARNING: Do not install unit where it would routinely
20
11
17
be splashed with water. Electric shock may result.
21
21
12
18
22
CAUTION: Hot water outlet pipes leaving unit can be
22
13
hot to the touch. Insulation must be used for hot water
19
23
23
14
pipes below 36" due to burn risk to children.
20
24
24
15
21
NOTICE: This unit should not be installed in a location
16
!
22
where it may be exposed to freezing temperatures
17
(less than 36 °F). If the unit may be subject to freezing
23
temperatures all water must be drained from the unit.
18
24
Failure to comply with this instruction voids all war-
19
ranties.
20
The unit should be located in an area where water
21
leakage from the unit or connections will not result in
damage to the area adjacent to the unit. If such a loca-
22
tion cannot be avoided it is recommended that a drain
23
pan be installed under the unit.
24
CAUTION: Hot water outlet pipes leaving unit can be
hot to the touch. Insulation must be used for hot water
pipes below 36" due to burn risk to children.
Install Tempra as close as possible to the main hot water draw-
off points.
1. Install Tempra in a frost free area. If frost might occur, re-
move unit before freezing temperatures set in.
2. Leave a minimum of 5" of clearance on all sides for servicing.
3. Remove the cover screw with a #2 Pozi-drive screwdriver and
open the cover .
WWW.STIEBEL-ELTRON-USA.COM
4. Mount unit securely to wall by putting at least three screws
through mounting holes
anchors for mounting on masonry or wood are provided.
A
1
2
3
1
B
10
11
4
2
12
5
13
3
14
6
C
4
15
16
7
5
17
8
D
E
18
6
19
9
Dimensions
7
20
21
A
⅜˝ / 10 mm
10
8
22
B
12½˝ / 318 mm
11
23
9
C
1˝ / 26 mm
24
12
D
¾˝ / 19.5 mm
10
E
7½˝ / 190 mm
13
11
F
7½˝ / 190 mm
14
12
3 /
G
˝ / 5 mm
16
15
13
16
14
17
15
18
16
19
17
20
18
1
1
2
1
2
3
. Screws and plastic wall
1
2
3
4
3
4
5
2
4
5
6
5
6
7
3
6
7
8
4
7
8
9
8
9
10
5
9
10
11
11
12
6
12
13
7
13
14
14
15
8
15
16
16
17
9
17
18
G
18
10
19
19
F
20
11
20
21
21
22
12
22
23
23
24
13
24
14
15
16
17
18
19
20
21
22
TEMPRA & TEMPRA PLUS |
5