BOILER PRESSURE - MANOMETER
The boiler pressure is adjusted between 0,9 bars and 1,2 bars.
An automatic regulation ensures the maintain of a constant pressure.
Turn the machine immediately off and call the maintenance service, if the boiler pressure is higher
than 1,5 bars.
NOTE:
The overheating thermostat will interrupt the boiler heating if the temperature increases
abnormally.

18. OPERATING DEVICES

COFFEE PUSH-BUTTONS
The machines features 5 coffee push-buttons:
1 espresso cup, 2 espresso cups, 1 standard cup, 2 standard cups, continious flow.
Each push-buttons could be programmed individually – see measure programming.
Press a push- button; the programmed coffee measure will be delivered. The flow can be stopped
by pressing again the same button. The led is lighting during the coffee delivery.
BUTTON ON/OFF: allows to produce coffee manually
This button is generally used if the electronic mother board is deffective.
STEAM TAP
Two manuals steam tap 'V' allows to heat liquids by injecting steam.
The liquid container should be high enough; the steam nozzle should soak into the liquid but not
touch the bottom
HOT WATER TAP
A manual tap 'E' allows to prepare hot water specialities (tea, grog, etc.)
FILTERS
The machine is supplied with 1-cup and 2-cup filters. Always ensure that the filters are unclogged
and clean. To remove used coffee grounds from the filter, turn the filter holder upside-down and
tap it lightly on the edge of a wooden box.
FILTER HOLDERS
Never take the filter holder off when the group is operating; ensure first that the liquid has
stopped flowing from the filterholder outlets.
Always leave the filter-holder on the machine with the filters filled with the coffee grounds of the
previous coffee to maintain the temperature of the filterholder.
When the machine is switched off for an extended period, remove the filter holders and expel the
used coffee grounds.