19.6.
6-1 Alarm Time Out 1st filling:
If the electronic does not receive information from the SN level probe for more than 400 seconds (at the
1st filling), the LED "L2" & "L3" of all groups will flash to indicate failure and the display indicates :
6-2 Flowmeter alarm :
If, during the distribution of coffee, the mother board does not receive pulses from a flowmeter for
more than 4 seconds, all LEDs of the concerned group start flashing to indicate failure and the display
indicates :
After 45 seconds, the machine automatically stops the solenoid valve of the concerned coffee group
and the pump also.
6-3 alarm temperature sensor disconnected :
If the mother board does not receive information from the temperature sensor for more than 3 seconds,
the electronics automatically cut off the solid state relay and leds "L1"& "L4" from all groups will flash
to indicate default. The display indicates :
6-4 Over temperature alarm:
If the electronics detects a temperature > 140 ° C f or more than 5 seconds in the boiler, the LEDs "L3" of
all groups will flash at the same time and the management of the heating is stopped automatically.
The display indicates :
The alarm is removed when the temperature drops below 125 ° C.
19.7.
If necessary, it is possible to re-configure the machine with data by default.
Procedure:
_ Turn off the power supply of the machine.
_ Keep pressing simultaneously the keys "P1 Gr1" + "P3 Gr1"+"P5 Gr1"
_ Turn the machine on.
_ When the display shows :
To return to normal operation, turn off and on the machine.
SACOME, CONFIDENTIAL Document,
DESCRIPTION OF THE ALARMS:
Time out Filling
Alarm Flowmeter
Group X
Temperature probe
not connected
Over temperature
steam boiler

RESETTING DATA:

Preset value
completed
Edition 07/2010 - CC100 DISPLAY