10. Operation
The "DOOR BELL" button is available as a doorbell. After pressing this button the con-
tacts "DOOR BELL" are shut. The current free door bell contact has a capacity of max.
30 V (AC/DC), 1 A.
The operation of your code lock depends on the specific programming. The following
example is based on the previous programming example.
Adapt the way you use the device to suit the settings that you have made.
Outputs are switched with the user code
The following entries relate to switching the outputs using each defined user code
8
3
2
6
8
5
9
2
7
Outputs are switched with the master code
The following entries relate to switching the outputs using the defined master code
2
3
8
2
3
8
2
3
8
1
#
4
#
0
#
9
#
1
9
#
2
9
#
3
Output 1 engages for 5 seconds
Output 2 toggles
Output 3 toggles
Output 1 engages for 5 seconds
Output 2 toggles
Output 3 toggles
.
.
61