3. Intended use

The code lock serves as a doorbell, a controller for doors, garage door motors etc., and
for monitoring and access recognition at entrance doors.
Because of its waterproof construction, you can use the device outside. Please avoid
direct contact with a water jet.
This product is only approved for use with AC/DC voltages of 12 to 24 V.
The maximum switching power of the "Output 1" relay must not exceed 5 A/30 V DC,
and that of the "Output 2" relay must not exceed 1 A/30 V DC. The "NPN-Open-Collec-
tor" outputs must not be loaded with more than 100 mA and 24 V DC.
The code lock has a sabotage contact ("TAMPER") that recognises opening of the
housing and can be used to activate an alarm system.
Any use other than one described above is not allowed and can damage the product.
Moreover, this involves dangers such as e.g. short-circuit, fire, electric shock, etc.
No part of the product may be modified or rebuilt!
The safety instructions must be observed at all times.

4. Scope of delivery

• Code lock
• Mounting material (4 screws, 4 dowels)
• 1 diode (e.g. 1N4004)
• Operating instructions