6) Should a phase reversal occur during the complete signal
transmission, this can be compensated by pressing the
PHASE switch (3). Sometimes it is possible to achieve the
correct setting by listening to the bass.
5 Specifications
Frequency range: . . . . . . . . . . . . . . . . . 20–25 000 Hz
Transformation ratio: . . . . . . . . . . . . . . 1:1/2:1
Input impedance: . . . . . . . . . . . . . . . . . 600 Ω
Output impedance: . . . . . . . . . . . . . . . . 600 Ω/150 Ω
Optimum source impedance: . . . . . . . . 50–600 Ω
Optimum load impedance: . . . . . . . . . . ≥ 2 kΩ
Max. input voltage at 1 % THD/40 Hz: . 5 V
Dimensions (W x H x D): . . . . . . . . . . . 482 x 44.5 x 90 mm,
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 kg
According to the manufacturer.
Subject to technical change.
1 HE (rack space)
GB
9