TrapSV open time
Max. current-1
Max. current-2
Choice of control
box
Acoustic alarm
Rot field fault
Service mode
Language
Settings
(bottom line)
0-60 sec.
0-16 A
0-16 A
Type OAE/RAE,
Type OA/RA,
Type OSE/RSE
Is activated,
is switched off
Is activated,
is switched off
Is activated,
is switched off
German, English...
Explanation
Time in which the magnetic valve opens
automatically twice a day and the odour trap
(fresh water filling unit) is provided with an
hydraulic seal.
Maximum power consumption for the HD
pump for cleaning the interior.
Automatic switching off of the HD pump
for cleaning the interior when the power
consumption setting is exceeded.
Maximum power consumption for the disposal
pump.
Automatic switching off of the disposal pump
when the power consumption setting is
exceeded.
Choice of control program for the respective
type of grease separator.
Activated: a buzzer sounds in the event of a
fault.
Activated: A buzzer sounds in the event of an
incorrect phase sequence or the absence of
a phase (L1, L2 or L3).
Settings which should be coordinated with
ACO Service.
Choice of language for the menu items.