Parker GL Plus Série Notice D'utilisation page 23

Filtre à air comprimé
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
Compressed air filter series GL Plus
Cleaning the float drain
Hazard due to a sudden release
of pressure!
Depressurise the filter before carrying
out any work on the filter! A sudden
escape of pressure may cause seri-
ous injuries.
- Block compressed air supply to the filter.
- Open the drain plug of the float drain to
depressurise the filter (Figure 3).
- Give the lower housing a full turn in clock-
wise direction and take it off downwards
(Figure 5).
- Replace seal (Figure 6).
- Using an open-ended spanner on the ou-
ter hexagon, unscrew the float drain out of
the lower section of the housing (Fig. 10).
- Insert a new or the cleaned float drain
into the lower section of the housing and
hand-tighten at the outer hexagon.
)
Do not overtighten the float drain (max.
tightening torque 2 Nm) otherwise the
filter could leak!
- Apply a thin coat of grease on the thread
of the lower housing.
- Using the marks, vertically align the lower
section with the upper section of the
housing and fully close off with one com-
plete turn (Fig. 8).
- Open the supply line to the filter.
- Check the filter for tightness. To do so,
close the drain plug of the float drain
(Figure 9).
GL Plus 2-19_Int1
Operating Instructions | EN
Remedy for malfunctions
Differential pressure gauge
After a pressure peak, e.g. when a valve was
opened abruptly, the needle of the differen-
tial pressure gauge is locked. The needle is
behind the stop in the red area.
Warning!
Make sure to check the filter element
since it may have been damaged.
Replace any damaged element.
Replacement of the filter element see
page 22.
After testing the filter element you must
reset the needle of the differential pressure
gauge:
- Carefully pry out the viewing glass on the
side of the stop pin with a screwdriver.
- Carefully lift the needle and move it back
over the stop.
- Insert the viewing glass again and push it
in until it is firmly seated.
Poor filtration performance
When the filtration performance is insuffici-
ent even with a new filter element, incorrect-
ly chosen conditions of application or flow
rates can be the reason. Contact your sales
partner to find a solution in such a case.