Troubleshooting; Specifications - Salvis Master VisionPRO Mode D'emploi

Masquer les pouces Voir aussi pour Master VisionPRO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en
5.

Troubleshooting

If faults should occur, check them using the following table:
Fault
The green indic­
ator light or the
light ring does not
illuminate when
the appliance is
turned on.
The appliance is
turned on and
does not heat up.
The device does
not heat but the
indicator lights or
the light ring are
illuminated.
If you can not resolve the fault,
− turn off the device and disconnect from the power,
− do not open the cover,
− contact customer service.
6.

Specifications

Specifications
Item no.
Total load
Voltage
Fuses
Overall thermal
output
Steam production
Appliance noise
level
We reserve the right to make technical changes.
16 / 28
Possible cause
Main switch on front of the appli­
ance is not turned on.
There is no power supply at all.
The circuit breaker has tripped.
An energy optimizing unit does
not switch the heater on.
Safety temperature limiter has
tripped.
Steel Range with large cooking field
2 heating zones
MA602100, VP602100
MA602150, VP602150
7 kW
400 V 3-phase 50/60 Hz
2 x 16 A
2.55 kW
1.08 kg / h
less than 70 dB (A)
Remedy
Turn on the main switch.
Contact power supplier.
Let authorized customer service check
the appliance for possible faults.
Reset the circuit breaker.
Check the energy optimizing unit.
Have the appliance checked by an electri­
cian or by customer service.
Steel Range with large cooking field
4 heating zones
MA602200, VP602200
14 kW
400 V 3-phase 50/60 Hz
(230 V 3 50/60 Hz)
2 connecting cables,
for each cable 2 x 16A
(230 V = 2 x 2 x 20 A)
5.10 kW
2.16 kg / h
less than 70 dB (A)

Publicité

Table des Matières
loading

Table des Matières