Replacing the sensor 3152.300

Depending on the size of the aquarium, the
Osmolator® nano sensor can function continuously
between 3 and 5 years. In case of a fault it can be
replaced in just a few steps.
Detach the catch hook of the sensor housing from
the magnet by pulling firmly (1).
Unscrew the nut of the sensor, slide the sensor with
the cable out of the opening (2).
Detach and open the controller by simultaneously
applying pressure to the points (3).
Unplug the connector in the controller (4) and
replace it with a new sensor 3152.300.
Push the controller/housing together again, remount
the sensor holder, and check the functionality!
Remplacement du capteur 3152.000
En fonction de la taille de l'aquarium, le capteur de
l'Osmolator® nano connaîtra une durée de vie de 3
à 5 ans. En cas de défaut, ce capteur se remplace
avec très peu de manipulations.
Déverrouillez les clips du Magnet en tirant fortement
sur la coquille (1).
Ouvrez l'écrou du capteur, sortez le capteur et son
câble de la coquille (2).
Ouvrez le Controller en appuyant fortement sur les
points (3).
Déconnectez la prise du capteur (4) et remplacez-le
par un nouveau capteur 3152.300.
Refermez le Controller, remontez le support du
capteur, vérifiez le fonctionnement!