PROGRAMMING PROCEDURE (Setting the programmer and the work times)
Attention! Before starting the gate/gate must be moved to the completely closed position
gate to this position.
• Make sure that display "D1" is off and the LEDs "L4", "L5", "L7" and "L8" are all lit .
• Open the "Standard wiring diagram" which is folded inside the last page of this manual and carry out the programming procedure.
D1
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE PARAMETER
DEFINITION LETTER "d" WILL APPEAR
ON THE DISPLAY (STAGE "A")
AFTER 1 SECOND THE DIGIT "1" WILL APPEAR
(FIRST PROGRAMMING STEP). THIS NUMBER
CAN BE EITHER FLASHING OR FIXED
ACTIVE
FUNCTION
PRESS
Dynamic button
PROG
open-close
Note 1
PRESS SEL
Automatic
PRESS
reclosing
PROG
enabled
PRESS SEL
Preflashing
PRESS
PROG
enabled
PRESS SEL
Travel limits
enabled
Note 2
PRESS SEL
Warning light
output
PRESS
fixed
PROG
PRESS SEL
Deceleration
PRESS
anabled
PROG
PRESS SEL
PRESS
SEL
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
1...4... sec.
Importing notes regarding the programmer settings
Note 1 Travel direction inversion only during the closing stage.
Note 2 Seeing as the operating mode of the programmer for the SL4024 is based
1... sec.
ACTIVE
FUNCTION
Dynamic button
open-block
close-block
Automatic
reclosing
excluded
Preflashing
excluded
Warning light
output
intermittent
Deceleration
excluded
PRESS
PROG
1...20... sec.
18
(Led L6 "FCC" off).
on travel limits it is obviously not possible to deactivate them. To leave the
programming order unaltered (this will help installers who are used to the
product) parameter number "4" has remained assigned to that function
even though that parameter cannot be modified.
PRESSING THE "PROG" BUTTON WILL MOVE YOU TO
STAGE "b" . PROGRAMMING THE DECELERATION TIME.
THE VALUES CAN BE CHOSEN FROM 2 TO 4 SECONDS.
ALTERNATING
ALTERNATING
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
SEL
PRESS
PROG
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
. Press the "SEL" button to move the
FIxED
VALUE
SELECTION
PRESS
2 SECONDS
PROG
FIxED
VALUE
SELECTION
PRESS
3 SECONDS
PROG
FIxED
VALUE
SELECTION
PRESS
4 SECONDS
PROG
PREMERE
SEL
1...20... sec.
CONTINUE ON PAGE 18