Manual Ignition (By The Gas Fitter) - MCZ FORMA GAS 55/75/95/115 Guide De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9.1 Manual ignition (by the gas fitter)

This action is intended for service purposes only.
Take the following steps:
1. Remove the ignition cable of the receiver (fig. 1.2-G) and place this on the gas block. (fig.1.3.2-D)
2. Twist the knob B to the right  with the arrow to the OFF position. (fig. 1.3.2)
3. Twist the dial A to the right  with the arrow in the MAN position (fig. 1.3.2). Now the pilot light valve
C and the piezo-ignition E are accessible.
4. Use a screwdriver to keep the pilot light valve C pressed in, simultaneously press the piezo-ignition E
(fig. 1.3.2) briefly a few times, the pilot light will ignite now.
5. If the pilot light is burning, wait for approx. 20 seconds before releasing the pilot light valve.
6. Now twist the dial A to the left  with the arrow to the ON position. (fig. 1.3.2)
7. Now the flame height can be adjusted by twisting the knob B to the left  past the ON position
(this causes a rattling sound!) (fig. 1.3.2).
FORMA GAS 55/75/95/115
USER MANUAL
Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
8
page

Publicité

Table des Matières
loading

Table des Matières