IMPORTANT NOTE: Installation of the Wolf
electric steamer module must meet the follow-
ing location requirements. All dimensions
listed are minimum requirements for safe
operation. Refer to the illustration below.
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above the
surface units should be avoided. If
cabinet storage is to be provided, the risk
can be reduced by installing a ventilation
hood that protects horizontally a
minimum of 127 mm beyond the bottom
of the cabinets.
E
F
Minimum installation clearances
6
S T E A M E R M O D U L E
P R E P A R A T I O N
C
G
D
A
B
L O C AT I O N I N C O U N T E R T O P
A)
Minimum flat countertop surface. Must be
equal to or greater than the width of the
module(s).
B)
Minimum 152 mm wide clearance from the
module side edge to any combustible
surface up to 457 mm above the countertop
(noted by shaded area).
O V E R H E A D C A B I N E T D I M E N S I O N S
C)
Minimum spacing between overhead side
cabinets must be greater than or equal to
the nominal width of the module(s).
D)
Minimum 457 mm vertical distance from
the countertop to the bottom of side
cabinets within minimum side clearance.
E)
Minimum vertical distance between the
countertop and combustible materials
above the module must be 762 mm.
F)
Minimum 25 mm from rear wall.
G)
Maximum 330 mm depth of overhead and
side cabinets directly above and within side
clearance.
Failure to locate the cooktop module
without the proper clearances will result
in a fire hazard.
B