Target Group; Intended Use - Parker Domnick Hunter GH Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN | Operating instructions
Series GH compressed air filters
Parker-dominik hunter high-pressure filter se-
ries GH are only designed for the high-pressure
range 100 or 350 bar. Due to a wide spectrum
of available element types, it is extremely
versatile.
The filter elements ZP, XP and A are flown
through from the inside to the outside. The
strainer filter V and the cartridge flow the gas
through from the outside to the inside.
Scope of delivery
The filter is supplied with a manual drain as
drain in the standard version. The filters are
supplied in a ready to operate condition and
can be installed directly into the pipe system.
Filters of the OA variant are supplied wit-
hout manual drain (needle valve) and cannot
be operated without mounted accessories.
Accessories that were ordered but are not de-
scribed here come in separate packages und
must be installed according to the respectively
enclosed instructions.

Target group

The present Operating Instructions are inten-
ded for specialists charged with installation,
operation and maintenance of the filter. Such
persons must be trained in handling pressure
devices and have basic knowledge of how to
handle pressure devices.
Product ID
The product designation for series GH high-
pressure filter is derived from the following
codes:
/
GH
4
High-pressure filter for compressed air
Examples:
GH 7 / 100 XP
GH 11 / 350 ZP OA
Size
3, 5, 7, 9, 11, 12, 13
Element type
V (strainer filter)
ZL (fine filter)
XL (ultra-fine filter)
A (activated charcoal filter)
KTA, KTM, KTY (cartridge)*
Options **
OA (without drain)
* available for filter sizes GH3-GH9
** only if not standard

Intended use

The information on the type label must be
observed. Non-observance of the data given
there is regarded as improper use. The filters
are suitable for filtering compressed air and
(gaseous) nitrogen within the limits of the
stipulated values.
Impermissible applications
The filtration of critical fluids is not permitted.
The filters must never be used for filtration
of explosive, flammable or noxious gases of
fluid group 1 according to Directive 2014/68/
EU. Changes to the pressure vessels are not
permitted. Modifications will endanger the
operational safety and may cause damage or
personal injury.
GH3-GH13_Rev.03