 Conclude with use of the welding menu by pressing OK.
 Dissipate the pressure completely by pressing the button (3).
 Unclamp the welded work pieces and remove them.
 Move the basic machine apart. The machine is ready for the next welding cycle.
Transferring the log :
In the Log menu item, these can be saved with OK, if a USB stick is connected. The window then closes
automatically. This report file should be processed using the VIDATA 2.0 software and a computer.
All welding parameters can be found in the enclosed welding tables.

3.2.5. Putting out of operation

 Use the button (6) to turn off the hydraulic unit.
Let the heating element cool or stow it in such a way that no adjacent materials can be ignited!
 Remove trimmer unit, heating plate and hydraulic unit mains plugs from power outlet and roll up cables.
Transport and set the hydraulic unit only in a horizontal position. If it is set at an angle, oil
escapes from the vented plugs with the dipstick!