Conclude with use of the welding menu by pressing OK.
Dissipate the pressure completely by pressing the button (3).
Unclamp the welded work pieces and remove them.
Move the basic machine apart. The machine is ready for the next welding cycle.
Transferring the log :
In the Log menu item, these can be saved with OK, if a USB stick is connected. The window then closes
automatically. This report file should be processed using the VIDATA 2.0 software and a computer.
All welding parameters can be found in the enclosed welding tables.
3.2.5. Putting out of operation
Use the button (6) to turn off the hydraulic unit.
Let the heating element cool or stow it in such a way that no adjacent materials can be ignited!
Remove trimmer unit, heating plate and hydraulic unit mains plugs from power outlet and roll up cables.
Transport and set the hydraulic unit only in a horizontal position. If it is set at an angle, oil
escapes from the vented plugs with the dipstick!