3.1.1. Basic unit (fig. A)

1 Movable clamps
2 Sliding clamps

3.1.2. Hydraulic unit (fig. B)

1 Automatic button
2 Pressure button
3 Pressure release button
4 Adjusting knob
5 Cutting button
6 ON/OFF button
7 Heating button
8 « Open » machine
9 Temperature and time display
10 Release button
11 « Close » machine
The hydraulic unit allows the operator to operate the welding machine and perform the functions indicated by
the following symbols::
Turning the hydraulic assembly on and off
Press the „Heating" button to turn the heating element on. Set the desired
heating element temperature by pressing the „Heating" button and turning the
adjustment knob. The value will be shown in the temperature display, and then
the current value is again shown.
Use the adjustment knob to set the pressure for cutting, aligning, heating and
joining.The value is shown in the „Pressure" display. Three seconds after the
settings are made, the current value is shown. Pressing the rotary knob displays
and allows changes to be made to the service parameters.
To bring the clamping elements together, press the release button and „close"
the machine.
Pressure release button
To separate the clamping elements, press the release button and „open" the
machine.
Press the release button and the cutting button to turn on the cutting unit
socket. Pressure is automatically set to 10 bar and can be increased to a
maximum of 20 bar using the adjusting knob. (In special situations, such as on
slopes, the pressure can be set to a maximum of 50 bar by changing P004.)
Activate the timer by pressing it once. By pressing the button and turning the
adjusting knob, the t1 time can be set in seconds. Pressing the button longer
switches over to t4. By pressing the button and turning the adjusting knob, the
t4 time can be set in minutes. The timer is started manually by shortly pressing
on the timer key if the timer indicator lights up with t1 or t2.
3 Spacer with locking notch
4 Heating element take off device
12 Timer button
13 Socket for cutting unit
14 Quick coupling for pipe collar
15 Quick coupling for plug
16 Heating element connector
17 Electric plug
18 Emergency OFF
19 Touch screen PC
20 Oil filling port with dipstick
21 USB connection
22 Basic machine plug and socket device