Faults
Fault
No pressure builds up in
the device
pump.
The nozzle does not
sure is present.
there is no atomization.
not close.
Liquid emerges without
the lever being activa-
ted.
Pressure gage is not indi- Pressure gage [16]
CFV:
pressure in the tank is
lower or equal to the
operating pressure of the
CFV.
pressure in the tank is
greater than the operating
pressure of the CFV.
Cause
The pump is not scre-
O-ring [19] on the
Diaphragm [20] is
defective.
defective.
Filter [22] and / or
-
nozzle [21] blocked.
Insert [52] is missing
defective.
O-ring [24] on the pres-
sure bolt not greased.
Defective pressure bolt
[25] or O-ring [24].
defective.
Pressure in the tank is
too low.
CFV [55] is soiled or
defective.
Remedy
Replace the O-ring. (Fig. 21).
Replace the diaphragm. (Fig. 21).
Clean or replace the valve disk. (Fig.
20).
.
Position the insert in the nozzle. (Fig.
18).
Grease the O-ring of the pressure
bolt.
re bolt or O-ring.
Sever attachments (at top, at bot-
tom, on right) [26]. (Fig. 24) Open
panel [27], unscrew pressure gage
[16] with wrench and replace. (Fig.
24).
re parts pouch [3]), push to the right
and insert panel [27]. (
Increase pressure in the tank to
more than the operating pressure of
the CFV.
Replace the CFV [55].
20
ENGLISH
(Fig.
(Fig. 22).
Replace the pressu-
.
-

Publicité