Terms And Abbreviations - KROHNE OPTIBAR PM 5060 C Manuel De Référence

Masquer les pouces Voir aussi pour OPTIBAR PM 5060 C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPTIBAR PM 5060 C

2.4 Terms and abbreviations

The following terms and abbreviations are used in this document.
URL
URL
URL
URL
Upper Range Limit
LRL
LRL
LRL
LRL
Lower Range Limit
URV
URV
URV
URV
Upper Range Value
LRV
LRV
LRV
LRV
Lower Range Value
SPAN
SPAN
SPAN
SPAN
Span
CAL SPAN
CAL SPAN
CAL SPAN
CAL SPAN
Calibrated Span
TD
TD
TD
TD
Turn Down
Example for TD
LRL
LRL= 0 bar
LRL
LRL
URL= 3 bar / 43.5 psi
URL
URL
URL
URV= 2 bar / 29 psi
URV
URV
URV
LRV
LRV
LRV
LRV= 0.5 bar / 7.25 psi
01/2021 - 4004819802 - MA OPTIBAR PM 5060 C R04 fr
Upper measuring range limit. Also called nominal range. The highest value
that can be measured by a particular device.
Lower measuring range limit. The lowest value that can be measured by a
particular device.
The calibrated measuring range or the highest adjusted measured value.
This value corresponds to the 20 mA signal.
The calibrated measuring range or the lowest adjusted measured value.
This value corresponds to the 4 mA signal.
Measuring span or measuring range. SPAN = URL – LRL
Calibrated or adjusted measuring span. CAL SPAN = URV – LRV. Also called
"cSPAN".
This is the span set to the 4...20 mA output.
The ratio from the measuring span to the adjusted measuring span.
TD= SPAN/(CAL SPAN) = (+URL)/(CAL SPAN)
The following applies: URV ≤ URL, CAL SPAN ≤ SPAN, TD ≥ 1
TD Turn Down
TD
TD
SPAN= 3 bar / 43.5 psi
SPAN
SPAN
SPAN
CAL SPAN= 1.5 bar / 21.75 psi TD
CAL SPAN
CAL SPAN
CAL SPAN
DESCRIPTION DE L'APPAREIL
TD= 2:1
TD
TD
www.krohne.com
2
19

Publicité

Table des Matières
loading