Operating Instructions
ELS Professional Card
Switch
Position
ON
1)
DIP.2.1
OFF
ON
1)
DIP.2.2
OFF
ON
1)
DIP.1.1
OFF
ON
DIP.1.2
OFF
1)
ON
1)
DIP.1.3
OFF
ON
DIP.1.4
OFF
1)
ON/ON
1)
ON/OFF
DIP.1.5/1.6
OFF/ON
OFF/OFF
ON
DIP.1.7
OFF
1)
ON
1)
DIP.1.8
OFF
1)
Factory.setting
38
Setting the DIP switches
Illustration
Function
DIP 1
DIP 2
ON
DIP
ON
Electrical.sensitive.or.pneumatic.safety.edge.connecte
1 2 3 4 5 6 7 8
1
2
DIP 1
DIP 2
ON
DIP
ON
FRABA.OSE.optoelectronic.sensitive.edge.connecte
1 2 3 4 5 6 7 8
1
2
DIP 1
DIP 2
ON
DIP
ON
Terminal.resistance.of.sensitive.edge.=.1.2.kOhm
1 2 3 4 5 6 7 8
1
2
DIP 1
DIP 2
ON
DIP
ON
Terminal.resistance.of.sensitive.edge.=.8.2.kOhm
1 2 3 4 5 6 7 8
1
2
DIP 1
DIP 2
Testing.of.the.safety.edge.when.it.contacts.the.floor..The.bottom.switch-off.point.of.
ON
DIP
ON
the.door.is.adjusted.when.the.door.contacts.the.floor..Pneumatic.safety.edge.
1
2 3 4 5 6 7 8
1 2
DIP 1
DIP 2
No.testing.of.the.safety.edge.and.no.adjustment.of.the.bottom.switch-off.point.
ON
DIP
ON
Electrical.or.FRABA.OSE.safety.edge.
1
2 3 4 5 6 7 8
1 2
DIP 1
DIP 2
Deactivate.at.the.bottom.end.limit.via.switching.pulse.from.the.electric,.pneu-
ON
DIP
ON
matic.or.optoelectronic.safety.edge
1
2
3 4 5 6 7 8
1 2
DIP 1
DIP 2
ON
ON
DIP
Switch-off.at.lower.end.limit.with.programmed.end.position
1
2
3 4 5 6 7 8
1 2
DIP 1
DIP 2
ON
DIP
ON
Move.up.to.the.top.end.limit.after.a.safety.sto
1 2
3
4 5 6 7 8
1 2
DIP 1
DIP 2
ON
DIP
ON
Move.clear.of.the.obstacle.after.a.safety.stop.with.a.clearance.time.Z1.=.2.s
1 2
3
4 5 6 7 8
1 2
DIP 1
DIP 2
Relieve.the.safety.edge.at.the.bottom.end.limit.(reversing).with.reversing.time.
ON
DIP
ON
Z5.=.100.ms
1 2 3
4
5 6 7 8
1 2
DIP 1
DIP 2
ON
DIP
ON
No.relief.(reversing).at.the.bottom.end.limit
1 2 3
4
5 6 7 8
1 2
DIP 1
DIP 2
Relay.1:.warning.light,.early.warning.only.
ON
DIP
ON
for.automatic.closing
1 2 3 4
5 6
7 8
1 2
DIP 1
DIP 2
Relay. 1:. traffic. lights,. door. at. top. end.
ON
DIP
ON
limit
1 2 3 4
5 6
7 8
1 2
DIP 1
DIP 2
Relay.1:.warning.light,.always.with.early.
ON
DIP
ON
warning
1 2 3 4
5 6
7 8
1 2
DIP 1
DIP 2
Relay. 1:. door. status,. door. at. top. end.
ON
DIP
ON
limit
1 2 3 4
5 6
7 8
1 2
DIP 1
DIP 2
Relay.1:.warning.light.flashing,.flash.rate.
ON
DIP
ON
1.Hz
1 2 3 4 5 6
7
8
1 2
DIP 1
DIP 2
ON
DIP
ON
Relay.1:.warning.light.on.continuously
1 2 3 4 5 6
7
8
1 2
DIP 1
DIP 2
Reduction.of.the.reclosing.time.Z4.to.3s.due.to.release.of.the.photoelectric.bar-
ON
DIP
ON
rier.
1 2 3 4 5 6 7
8
1 2
DIP 1
DIP 2
ON
DIP
ON
Due.to.release.of.the.photoelectric.barrier.the.reclosing.time.Z4.is.reset.
1 2 3 4 5 6 7
8
1 2
Relay.2:.yard.light
Relay.2:.yard.light
Relay.2:.yard.light
Relay. 2:. door. status,. door. at. bottom.
end.limit
Relay.2:.yard.light,.control.pulse.1.s
Relay. 2:. yard. light,. remaining. on. for.
120.s.(time.Z6)