Product Description; Technical Data - Burkert 6014 Manuel D'utilisation

Masquer les pouces Voir aussi pour 6014:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.
PRODUCT DESCRIPTION
The direct-acting solenoid valve Type 6014 is available in two designs.
Type 6014 is used for the blocking, dosing, filling and
venting of neutral gaseous and liquid media, in par-
ticular for controlling single-acting pneumatic actuators
or technical vacuum. The modular designed valve can
be installed individually or in a block on the multiple
manifold.
Type 6014P is used as a special pilot valve for direct
installation on the externally controlled pneumatic actu-
ators. It consists of the magnetic actuator Type 6014
and a special body with hollow screw which can be con-
nected directly to the pilot air port of the actuator. The
valve features manual actuation as standard.
5.4. Mechanical data
Dimensions
See data sheet
Materials
Body
Type 6014
Type 6014P
Hollow screw
Type 6014P
Base plate
Type 6014P
Sealing
Type 6014
Type 6014P
Port connection
Type 6014
Type 6014P
Hollow screw G1/8, G1/4
6
Medium temperature
FKM
-10 – +100 °C (PA coil)
-10 – +120 °C (Epoxid coil)
Viscosity
max. 21 mm²/s
5.6. Type label
Orifice
Circuit function
Type
6014 C 1,5 FKM MS
G1/8 PN 0-16 bar
24V
50 Hz
00450000
Identifications number
Voltage / frequency / power
Port connection / nominal pressure
Fig. 1:
Type label (example)
brass, stainless steel 1.4305,
polyamide (PA, flange)
brass, polyamide (PA)
brass nickel-plated
aluminium anodized
aluminium anodized or IXEF
FKM, EPDM on request
FKM
G1/8, G1/4, flange
G1/8, G1/4
Sealing material
Body material
8W
CE
W14UN
5.
TECHNICAL DATA
5.1. Conformity
In accordance with the EC Declaration of conformity, the solenoid valve
Type 6014 is compliant with the EC Directives.
5.2. Standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity.
5.3. Operating conditions
WARNING!
Risk of injury from discharge of medium and pressure.
▶ If the device is used outdoors, do not expose it unprotected to the
weather conditions.
▶ Avoid heat sources which may cause the allowable temperature
range to be exceeded.
Ambient temperature
-10 – +55 °C
Degree of protection
IP65 in accordance with EN 60529 with
cable plug
5.5. Fluidic data
Circuit functions
2(A)
C
3/2-way valve, direct-acting,
(NC)
normal output A unloaded
1(P) 3(R)
2(B)
D
3/2-way valve, direct-acting, normal
(NO)
output B pressurized
1(P) 3(R)
2(A)
3/2-way valve, direct-acting,
T
universal valve
1(P) 3(R)
Tab. 1:
Circuit functions
Pressure range
see type label
Media
neutral gaseous and liquid media (e.g. compressed
air, town gas, natural gas, water, hydraulic fluid,
petrol, technical Vacuum), which do not attack body
and sealing materials
(see Chemical Resistance Chart www.burkert.com)
5.7. Electrical data
Connection
DIN EN 175301-803 (DIN 43 650), form A
for cable plug Type 2508
Operating voltage
24 V DC ± 10 % - max. residual ripple 10 %
24 V / 50 Hz
230 V / 50 Hz
Voltage tolerance
± 10 %
Nominal output
8 W
Impulse version
7 W
Nominal operating mode 100 % continuous operation
for block installation
5 W continuous operation on request
8 W intermittent operation 60 % (30 min)
Type 6014
5
7

Publicité

Table des Matières
loading

Table des Matières