Pentatech 3000 SET F4 Instructions D'installation page 42

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

# During disarmed status the system monitors the detectors. If a battery
compartment lid is removed, eg. a from contact is removed from the
door frame, then the detector sends tamper alarm signal to the panel.
14. Settings
The system is factory set as follows:
delay for delayed detectors
delay for other detectors
volume of panel siren
alarm period
user code
language
key tone
* to change the language see chapter 12
Settings can be changed and set only by sending SMS commands from the
numbers stored with SMS "5" and "6" to the number of SIM card in the
panel. The SMS commands can also be send using the Application (App see
side 1). Further SMS command texts are listed in chapter 12.9.
A detailed description of the operation via SMS can be found
on the sheet enclosed.
SMS text
command
00
status enquiry
?
Enquiry menu 1
??
Enquiry menu 2
???
Enquiry menu 3
5*
store numbers
for alarm calls
6*
store numbers
for alarm SMS
7*
store number
to receive SMS
for RFID disarm
8*
Preset number
91-99*
name detectors
1-9
101-104*
SMS text
for RFID disarm
11*
delay for other
detectors
12*
volume and
period of alarm
42
30 seconds
0 seconds (=immediate alarm)
2 (normal)
3 minutes
1 2 3 4
German*
activated
reaction
status and settings sent by SMS
first menu side sent by SMS (SMS 0 /
1 / 2 / 3 / 4 / 00 / ??)
second menu side sent by SMS
(SMS 5/6/7/8/???)
third menu side sent by SMS
(SMS 91-99/101- 104 / 11 / 12 / 13
/ 14)
per SMS enter max. 5 numbers for
setting and for receiving alarm calls
per SMS enter max. 5numbers for
setting and for receiving alarm SMS
(no. Stored as "1." will be sent SMS
upon mains power failure)
per SMS enter 1 number which
receives SMS for disarm with RFID
tag**
per SMS enter 1 preset number
per SMS name detectors 1 to 9
(for detectors 10 to 50 the text
remains: detector X Alarm)
per SMS enter SMS text (max. 30
tokens), to be sent when disarming
with the first 4 enrolled RFID tags**
per SMS enter the entry/exit delay
(0 to 300 seconds - usually leave as
factory default=0)
per SMS enter values
(volume: 0 = off, 1 = quiet, 2=
normal; period: 1 to 9 minutes)
13*
change user code
14*
delay for delayed
detectors
21
delete all detectors per SMS delete all wireless detectors
22
delete all RFID tags per SMS deleteall RFID tags
23
delete all remote
controls
30
deactivate key tones per SMS deactivate the key tones
31
activate key tones
0000
Reset
0001
English
* for all commands marked * the SMS received from the panel must be
edited and then forwarded to the panel, in order to store the
changes/settings. The successful change/setting will be confirmed by
SMS.
Note: Do not use spaces while editing and forwarding the SMS.
** to enable this function both the settings SMS "7" and SMS "101-104"
must be completed
*** a reset can also be made by pressing the tamper switch
[16] 5 times within 3 seconds.
Example: store numbers for alarm SMS
send SMS
:
6
SMS:
1.
2.
3.
4.
5.
Edit the received SMS and then forward it
Note:
Do NOT insert any space or any "+"
symbol before the number (enter
eg.0049...)
Store alarm SMS No.
successfully.
per SMS enter new user code
per SMS enter delay
(0 to 300 seconds, 0= no delay)
per SMS delete all remote controls
per SMS activate the key tones
all settings back to factory default ***
per SMS set the SMS language to
English
SMS:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.

Publicité

Table des Matières
loading