2.7. Safety and control devices
Our products are equipped with various safety and control devices. These devices must never be dismantled or
disabled.
Equipment must be checked by an electrician for proper functioning before start-up (see the "Electrical
Connection" data sheet). Please remember that certain equipment requires a decoder device or relay to function
properly. This decoder can be obtained from the manufacturer or a specialist electronics dealer.
Personnel must be informed of the installations used and how they work.
Caution
Never operate the machine if the safety and monitoring devices have been removed or damage, or if they
do not work.
2.8. Pumped fluids
Each pumped fluid differs in regard to composition, corrosiveness, abrasiveness, total solid content and many
other aspects. Generally, our products can be used for many applications. For more precise details, see chapter
3, the machine data sheet and the order confirmation. It should be remembered that if the density, viscosity or the
general composition change, this can also alter many parameters of the product.
Different materials and impeller shapes are required for different pumped fluids. The more exact your
specifications on your order, the more exactly we can modify our product to meet your requirements. If the area of
application and/or the pumped fluid change, we will be happy to offer supportive advice.
When switching the product into another pumped fluid, observe the following points:
Products which have been operated in sewage or waste water must be thoroughly cleaned with
pure water or drinking water before use.
Products which have pumped fluids which are hazardous to health must always be decontaminated
before changing to a new fluid. Also clarify whether the product may be used in a different pumped
fluid.
With products which have been operated with a lubricant or cooling fluid (such as oil), this can
escape into the pumped fluid if the mechanical shaft seal is defective.
Danger - explosive fluids!
It is absolutely prohibited to pump explosive liquids (e.g. gasoline, kerosene, etc.). The products are not
designed for these liquids!
2.9. Sound Pressure
Depending on the size and power (kW), the pump has a sound pressure of about 40dB (A) to 70dB (A) during
operation. However, the actual sound pressure depends on several factors. These are, for example, the type of
installation and set-up, mounting of accessories, piping, operating point, immersion depth, and much more.
3. General description
3.1. Application
The pumps are suitable for conveying clean or soiled water with abrasive contamination with sand or sludge.
Scope of application: for example gravitation drainage, dewatering of construction sites, subways or sewers,
emergency use in the event of flooding.
With chemically aggressive components in the pumped medium the resistance of the pump materials must be
noted without fail. The pumps are suitable for both mobile and stationary operation. Free-standing installation on
firm base is possible.
The minimal level of the medium must always be above the upper edge of the suction filter. Use in slurp mode is
not permitted.
The temperature of the pumped medium may be up to 35°C, short-term up to 60°C maximum. The maximum
density of the pumped medium is 1,100 kg/m3 and the pH value may be 6 to 8.
3.2. Type of Use
The pumps are designed for 40% S3 intermittent operation.
8